Service the PA-5200 Series Firewall
STEP 3 |
Confirm that the failed drive is removed from all parons. In the following output of the
show system raid detail, you see that drive id Sys1 is now missing from all
parons.
admin@PA-5220> show system raid detail
Overall System Drives RAID status
-----------------------------------------------------------------------------
Drive status
Disk id Sys1
(MICRON_M510DC_MT)
Disk id Sys2
(MICRON_M510DC_MT)
-----------------------------------------------------------------------------
Partition status
panlogs
Drive id Sys2
maint
Drive id Sys2
sysroot0
Drive id Sys2
sysroot1
Drive id Sys2
pancfg
Drive id Sys2
panrepo
Drive id Sys2
swap
Drive id Sys2
STEP 4 |
Press the ejector buon on the drive carrier to release the carrier handle and gently pull the
handle toward you to remove the carrier and drive.
STEP 5 |
Remove the replacement drive from the packaging, determine the drive model, and place it
on an anstac surface. Then compare this model number with the model number of the
failed drive to determine which replacement procedure to use in 7.
PA-5200 Series Next-Gen Firewall Hardware Reference
degraded
Present
Present
clean, degraded
active sync
clean, degraded
active sync
clean, degraded
active sync
clean, degraded
active sync
clean, degraded
active sync
clean, degraded
active sync
clean, degraded
active sync
44