Service the PA-5200 Series Firewall
STEP 9 |
Different model replacement drive only) Add the replacement drive (that is a different model
than the failed drive) to the RAID 1 array:
When you iniate the copy command as described in the following steps, logging
stops and you cannot view logs unl the copy is complete and the disk pair shows
Available.
1.
(Oponal)
configuraon.
The firewall will fail over when the copy process in this procedures starts but you
can choose to
drive before you connue.
2. Copy the data from the other drive in the RAID 1 array to the replacement drive. In this
example, run the following command to copy the data from the Log2 drive to the Log1
drive:
admin@PA-5020> request system raid copy from log2 to log1
3. Run the following CLI command to view the status of the copy:
admin@PA-5020> show system raid detail
Periodically run this command unl the copy is complete and the Disk Pair Log
shows Available.
At this point, the Log2 drive shows not in use because the drive models are
not the same.
Disk Pair Log
Status
Disk id Log1
Disk id Log2
PA-5200 Series Next-Gen Firewall Hardware Reference
Suspend the firewall with the failed drive if it is the acve firewall in an HA
Verify Failover
model
: ST2000NX0999
size
: 1907729 MB
status
: active sync
model
: ST2000NX0253
size
: 1907729 MB
or manually suspend the firewall with the failed
Available
clean, degraded
Present
Present
41
2021 Palo Alto Networks, Inc.
©