PaloAlto Networks PA-5200 Seriesp Hardware Reference Manual page 38

Next-gen firewall
Table of Contents

Advertisement

Service the PA-5200 Series Firewall
Disk id Log1
model
size
status
Disk id Log2
model
size
status
STEP 2 |
Remove the failed drive from the RAID 1 array configuraon. In this example, run the
following command to remove the Log1 drive from the array:
admin@PA-5020> request system raid remove log1
STEP 3 |
Press the ejector buon on the drive carrier to release the carrier handle and gently pull the
handle toward you to remove the carrier and drive.
The illustraon shows how to remove a system (SYS) drive. The procedure to remove a log
drive is the same.
STEP 4 |
Remove the replacement drive from the packaging and determine the drive model. You will
compare this model number with the model number of the failed drive to determine which
replacement procedure to use in 7.
PA-5200 Series Next-Gen Firewall Hardware Reference
: ST2000NX0253
: 1907729 MB
: failed
: ST2000NX0253
: 1907729 MB
: active sync
38
Present
Present
2021 Palo Alto Networks, Inc.
©