2-8 JUMPER DEFINITIONS

• The figure below shows the location for the motherboard's jumper blocks.
CAUTION
• Do not move the jumper with the power on. Always turn off the power and
unplug the power cord from the computer before changing the jumper.
Otherwise, the motherboard could be damaged.

2-8.1 ONBOARD FAN CONNECTOR (FAN1/FAN2)

FAN1/FAN2: ONBOARD FAN CONNECTOR (12V)
CPU FAN
SYSTEM FAN
Those connectors support processor/system cooling fan with +12V.
Those support three pin head connector. When connecting the wire
to FAN connectors, user should give attention that the red wire is
the positive and should be connected to the +12V, the black wire is
Ground and should be connected to GND. If your motherboard has
Hardware Monitor chipset on-board, you must use a specially de-
signed fan with speed sensor to take advantage of this function.
For fans with fan speed sensor, every rotation of the fan will send
out 2 pulses. System Hardware Monitor will count and report the
fan rotation speed.
NOTE 1: Always consult vendor for proper CPU cooling fan.
NOTE 2: CPU FAN supports the FAN control. You can install PC
Alert utility. This will automatically control the CPU FAN
speed according to the actual CPU temperature.
FAN1
FAN2
GND
+12V
SENSOR
75KAV/75KAV-X
23