Sign In
Upload
Manuals
Brands
Omron Manuals
Accessories
F150
Omron F150 Manuals
Manuals and User Guides for Omron F150. We have
2
Omron F150 manuals available for free PDF download: Operation Manual, Brochure
Omron F150 Operation Manual (226 pages)
Visual Inspection System
Brand:
Omron
| Category:
Analytical Instruments
| Size: 3 MB
Table of Contents
Table of Contents
4
Precautions
7
Safety Precautions
8
General Precautions
9
Section 1 the Expert Menu Mode
10
The Expert Menu Mode
10
Features
11
Density Searches
13
Measurement Methods
13
Binary Center of Gravity and Area
15
Binary Axis Angle
16
Density Searches
18
Position Compensation
18
Binary Axis Angle
19
Binary Center of Gravity and Area
19
Rotational Position Compensation
20
Overview of F150 Installation and Operation
21
Documentation Conventions
22
Terminology
22
Section 2 Basic Operations
23
Basic Operations
23
Starting
24
Starting and Quitting
24
Flow of Operation
28
Operating Modes
28
Quitting
31
Menu Operations
33
Menu Operations
34
Screen Displays
35
Menu Tree
36
Inputting Values
37
Using Auto Menu Data
38
Section 3 Operating Procedures
39
Operating Procedures
39
Menu Tree
40
Adjusting Images
41
Adjusting Images
42
Filtering
42
Background Suppression
43
Output Calibration
45
Registering and Clearing Images
49
Registering Sample Images
50
Clearing Images
51
Using the STEP Signal
51
Filtering
52
Position Compensation
52
Background Suppression
53
Density Searches
55
Binary Center of Gravity and Area
59
Binary Axis Angle
65
Checking Settings
71
Rotational Position Compensation
72
Density Searches
75
Measurement Region Functions
75
Binary Center of Gravity and Area
80
Binary Axis Angle
86
Checking Measurement Conditions
92
Settings Outputs
93
Terminal Block Outputs
93
RS-232C Outputs
104
Checking Measurements
110
Monitor Mode
110
Adjusting Criteria for Measurement Regions
112
Adjusting Criteria for Output Expressions
113
Changing Search Intervals and Levels
115
Measuring
117
Run Mode
117
Adjusting Criteria for Measurement Regions
119
Adjusting Criteria for Output Expressions
120
Changing Search Intervals and Levels
122
Changing Scenes
124
Displaying Memory Images
126
System Menu
128
Saving/Loading System and Scene Data
129
Saving/Loading Image Data
134
Image Storage
136
Startup Scene and Mode
137
Checking the Software Version
138
Section 4 Terminal Blocks
140
Terminal Blocks
140
I/O Formats
141
Inputs
141
Outputs
141
No Handshaking
142
Terminal Signal Operation and Timing
142
Using Handshaking
146
Communications Settings
148
Section 5 Rs-232C Normal Settings
150
Communications Settings
151
Flowcharts
151
Command List
156
Input Format
157
AREAPARA: Area Parameter
158
Input Commands
158
AXISPARA: Axis Parameter
160
DATASAVE: Data Save
163
EXP: Expression
163
EXPPARA: Export Parameter
164
MEASDATA: Measure Data
165
MEASURE: Measure
166
POSIDATA: Position Data
167
RESET: Reset
169
SCENE: Scene
169
SCNLOAD: Scene Load
170
SRCHPARA: Search Parameter
170
Measurement Results Output Format
172
Section 6 Rs-232C Host Link Settings
173
RS-232C Host Link Settings
173
Communications Settings
174
Flow Chart
174
Setting Methods
177
Sample Programming
181
Command Tables
184
0010: Measurement
187
0011: Continuous Measurement
187
0012: Stop Measurement
187
0020: Switch Scene
187
0021: Increment Scene
187
Host Link Commands
187
0022: Decrement Scene
188
0023: Read Scene Number
188
0066: Save Data
188
0092: Reset
188
1000: Set X Criteria for Density
189
1001: Set y Criteria for Density
189
1002: Set Correlation for Density
190
1010: Read X Criteria for Density
190
1011: Read y Criteria for Density
191
1012: Read Correlation for Density
191
1020: Set X Criteria for Gravity
192
1021: Set y Criteria for Gravity
192
1022: Set Area Criteria for Gravity
193
1023: Set Binary Level for Gravity
193
1030: Read X Criteria for Gravity
193
1031: Read y Criteria for Gravity
194
1032: Read Area Criteria for Gravity
195
1033: Read Binary Level for Gravity
196
1040: Set X Criteria for Angle
196
1041: Set y Criteria for Angle
197
1042: Set Angle Criteria for Angle
197
1043: Set Area Criteria for Angle
198
1044: Set Binary Level for Angle
198
1050: Read X Criteria for Angle
198
1051: Read y Criteria for Angle
199
1052: Read Angle Criteria for Angle
200
1053: Read Area Criteria for Angle
200
1054: Read Binary Level for Angle
201
1100: Set Terminal Expression Criteria
202
1101: Set Rs-232C Expression Criteria
202
1110: Read Terminal Expression Criteria
203
1111: Read Rs-232C Expression Criteria
203
1200: Read Stored Image Judgement
204
1201: Read X for Stored Image
205
1202: Read y for Stored Image
206
1203: Read Angle for Stored Image
207
1204: Read Stored Image Area/Correlation
207
1210: Read X Displacement
208
1211: Read y Displacement
209
1212: Read Angular Displacement
209
1220: Read Terminal Expression Result
210
1221: Read Rs-232C Expression Result
211
Output Format
212
RS-232C Menu Operation Settings
214
Troubleshooting
217
Index
221
Revision History
226
Advertisement
OMRON F150 Brochure (8 pages)
Double-speed camera system VISION SENSOR
Brand:
OMRON
| Category:
Accessories
| Size: 0 MB
Advertisement
Related Products
OMRON F160-2 - 2
OMRON F150-3 - 2
Omron F10
Omron F150-2
Omron F10-S50R
Omron F10-S30R
Omron F10-S15R
Omron F10-S05R
Omron F3SJ-A1115N20
Omron F3SJ-A0520P30
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL