Amc Bays; Amc Bay Address; Amc B1 Channel Assignment - Kontron AdvancedTCA AT8901M User Manual

Table of Contents

Advertisement

AT8901M
3.3

AMC Bays

Two AMC bays for standard or custom AMCs mid-size and single width are implemented with
B+ connectors, which are compliant to the AMC.0 R1.0 specification.
Following AMC Geographic Addresses are implemented:
Table 3-9:

AMC Bay Address

AMC
AMC Bay ID
1
B1
2
B2
The state of each GA signal is represented by G (grounded), U (unconnected) or P (pulled up
to management power).
Table 3-10: AMC B1 Channel Assignment
Channel
Region
0
GbE
1
GbE
2
SATA/FC
3
SATA/FC
4
Fabric
5
Fabric
6
Fabric
7
Fabric
8
Fabric
9
Fabric
10
Fabric
11
Fabric
12
Extended
13
Extended
14
Extended
15
Extended
17
Extended
18
Extended
19
Extended
20
Extended
TCLKA
Clock
TCLKB
Clock
TCLKC
Clock
GA [2..0]
IPMB-L Address
UGU
UUG
Connection
Local Base Switch 0/21
Remote Base Switch 0/22
AMC B2, channel 2
RTM, STOR0
-
-
-
-
-
-
-
-
-
RTM, AMC_B1_P13
RTM, AMC_B1_P14
RTM, AMC_B1_P15
RTM, AMC_B1_P17
RTM, AMC_B1_P18
RTM, AMC_B1_P19
RTM, AMC_B1_P20
From backplane CLK3A
To backplane CLK2A or CLK2B
From backplane CLK3B
Page 3 - 9
Hardware Description
7Ah
7Ch
AT8901M User Guide

Advertisement

Table of Contents
loading

Table of Contents