AT8901M
In order to use the Fast Ethernet management port for CLI telnet access, an IP address must
be assigned. This implies that at least the first CLI access has to be done by Serial Console in
order to configure the serviceport IP settings. The corresponding procedure is described in the
following. User input is printed in bold letters.
1. Connect to serial port on AT8901M front plate using the adapter described in Chapter 3,
section 3.1.
Port settings are:
9600 bps
8 bit, no parity, 1 stop bit (8N1)
no flow control
2. Ensure that the board is powered up.
3. Wait for boot process to complete, i.e. until the console selection menu appears.
b - connect Base Fabric console
r - reset system
4. Type " b" to connect to the Base Fabric console.
Connected to Base Fabric console
Press ^X or ^V to get to menu again
Base fabric switching application Release GA 3.06 starting
(Unit 1)>
User:
5. Log in as admin and enter privileged mode (no passwords required by default).
User:admin
Password:
(Base Fabric) >enable
Password:
(Base Fabric) #
6. Set IP address and netmask (see below for an example IP address setting).
(Base Fabric) #serviceport ip 192.168.168.42 255.255.255.0
(Base Fabric) #
The FE management interface is available as from now.