Dometic Go Power GP-ISW-200 User Manual page 14

Pure sine wave inverter
Table of Contents

Advertisement

GP-ISW-400 Specification
2-3-3.
Electrical
Specification
Electrical
Voltage
Input
Voltage Range
No Load Current
Input
Power Saving Mode
Efficiency (Typ.)
On Mode @ Save Mode
On Mode @ No Load Mode
Continuous Output Power
Max. Output Power (1Min.)
Output
Surge Power (1Sec.)
Output
Frequency
Output Voltage
Short-Circuit Protection
Output Waveform 
Input Over-Voltage
Protection 
Input Under-Voltage
Protection
Protection
Protection
BAT. Low Shutdown
BAT. Low Alarm
BAT. Low Restart
BAT. High Shutdown
Environment
BAT. High Restart
Working Temp. 
Environment
Storage Temp.
Working Humidity
Safety &
EMC
Safety Standards
Safety &
EMC
EMC standards
E-mark
Dimension(WxHxD)
Others
Weight
Others
Remote Control
Cooling
Note: :
 Normal load Condition:Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% load
(PF=1.0)
 Voltage performance:Please refer to Figure 2
 Temperature performance:Please refer to Figure 3
[page 14] | gpelectric.com
Specification
GP400 Specification
Item
Voltage
Item
GP400-112
Voltage Range
No Load Current
Power Saving Mode
10.5~16.0VDC
Efficiency (Typ.)
<1A @12VDC
On Mode @ Save Mode
<0.2A @12VDC
On Mode @ No Load Mode
Continuous Output Power
<1A @12VDC
Over Rated Power
<0.2A @12VDC
(1 Min.)
Peak Power (3 Sec.)
Frequency
Output Voltage
Short-Circuit Protection
Output Waveform
Input Over-Voltage
Protection
16.0 ± 0.3VDC
Input Under-Voltage
Protection
BAT. Low Shutdown
10.5 ± 0.3VDC
BAT. Low Alarm
10.5 ± 0.3VDC
BAT. Low Restart
10.5 ± 0.3VDC
BAT. High Shutdown
14.5V± 0.3V
BAT. High Restart
16.0 ± 0.3VDC
Working Temp.
Storage Temp.
12.5V± 0.3V
Working Humidity
Safety Standards
EMC standards
E-mark
Dimension(WxHxD)
Weight
Remote Control
Cooling
Table 2. GP-ISW-400 for output 100/110/115/120 VAC Specification
Table 4. GP400 for output 100/110/115/120 VAC specification
GENERAL INFORMATION
Model No.
GP-ISW-400-12 GP-ISW-400-24
Model No.
12VDC
GP400-124
10.5~16.0VDC
< 1A @12VDC
12VDC
< 0.2A @12VDC
21.0~32.0VDC
88%
10
<0.5A @24VDC
< 1A @12VDC
<0.1A @24VDC
< 0.2A @12VDC
88%
400 W (± 3%)
<0.5A @24VDC
> 400 W~460 W (100%~115%)
<0.1A @24VDC
400 W (± 3%)
> 400 W~460 W (100%~115%)
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
100 / 110 / 115 / 120 VAC ± 5%
(Dip Switch Selectable)
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
1 second shutdown
100 / 110 / 115 / 120 VAC ± 5% (Dip Switch Selectable)
Pure Sine Wave (THD < 5%@ Normal Load)
1 Sec Shutdown
Pure Sine Wave (THD < 5%@ Normal Load)
16.0VDC ± 0.3VDC
32.0 ± 0.5VDC
10.5VDC ± 0.3VDC
10.5VDC ± 0.3VDC
21.0 ± 0.5VDC
10.5VDC ± 0.3VDC
21.0 ± 0.5VDC
14.5VDC ± 0.3V
21.0 ± 0.5VDC
16.0 ± 0.3V
12.5VDC ± 0.3V
28.0 ± 0.5VDC
32.0 ± 0.3VDC
-20˚C ~ 40˚C
-30˚C ~ 70˚C
25.0V± 0.3V
10~95% RH, non-condensing
-20 ℃~40 ℃
Certified UL 458
-30 ℃~70 ℃
(UL only for GFCI receptacles)
10~95% RH, non-condensing
Certified UL 458
Certified FCC class B
(UL only for GFCI receptacles)
Certified FCC class B
150 mm X 68mm X187 mm
150 mm X 68mm X187 mm
CR-8 (optional)
GP-SWR-A or GP-ISW-R
CR-8 (optional)
Temperature & Load Controlled cooling Fan
Temperature & Load Controlled cooling Fan
24VDC
GP400-148
2 1.0~32.0VDC
< 0.5A @24VDC
24VDC
< 0.1A @24VDC
42.0~64.0VDC
89%
<0.25A @48VDC
< 0.5A @24VDC
<0.05A @48VDC
< 0.1A @24VDC
89%
<0.25A @48VDC
<0.05A @48VDC
800 W
< 800 W
32.0 ± 0.5VDC
64.0 ± 1.0VDC
21.0VDC ± 0.5VDC
21.0VDC ± 0.5VDC
42.0 ± 1.0VDC
21.0VDC ± 0.5VDC
42.0 ± 1.0VDC
28.0VDC ± 0.5VDC
42.0 ± 1.0VDC
32.0VDC ± 0.3VDC
25.0VDC ± 0.3V
56.0 ± 0.5VDC
64.0 ± 0.3VDC
50.0± 0.3V
----
----
1.3kg
1.256kg
48VDC
90%
----
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go power gp-isw-400

Table of Contents