Voltage And Temperature Performance - Dometic Go Power GP-ISW-200 User Manual

Pure sine wave inverter
Table of Contents

Advertisement

GENERAL INFORMATION

2.5 VOLTAGE AND TEMPERATURE PERFORMANCE

GP-ISW-200 Specification
Electrical
Input
Output
Protection
Environment
Safety &
EMC
Others
Specification
Item
Voltage
Voltage Range
No Load Current
Power Saving Mode
Efficiency (Typ.)
On Mode @ Save Mode
On Mode @ No Load Mode
Continuous Output Power
Over Rated Power
(3 Min.)
Peak Power (3 Sec.)
Surge Power (3 Sec.)
Frequency
Output Voltage
Short-Circuit Protection
Output Waveform
Input Over-Voltage
Protection
Input Under-Voltage
Protection
BAT. Low Shutdown
BAT. Low Alarm
BAT. Low Restart
BAT. High Alarm
BAT. High Shutdown
BAT. High Restart
Working Temp.
Storage Temp.
Working Humidity
Safety Standards
EMC standards
E-mark
Dimension(WxHxD)
Weight
Remote Control
Cooling
Note:
This test condition is normal DC input and temperature 25˚C
Model No.
GP-ISW-200-12 GP-ISW-200-24
12VDC
10.0~16.0VDC
< 0.5A
< 0.12A
89%
< 0.12A
< 0.5A
200 W
230 W
250 W
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
100 / 110 / 115 / 120 VAC ± 5%
(Dip Switch Selectable)
2 seconds and restart 3 times shutdown
Pure Sine Wave (THD < 3%@ Normal Load)
16.0VDC ± 3%
10.0VDC ± 3%
10.0VDC ± 3%
10.5VDC ± 3%
12.5VDC ± 3%
15.5VDC ± 3%
16.0VDC ± 3%
14.5VDC ± 3%
-20˚C ~ 60˚C
-30˚C ~ 70˚C
10~95% RH, non condensing
----
Certified FCC class B
----
150 mm X 68mm X187 mm
1.6kg
CR-8 (optional)
GP-SWR-A
Temperature & Load Controlled cooling Fan
Table 1. GP-ISW-200 Specification
24VDC
2 0.0~32.0VDC
< 0.4A
< 0.06A
91%
< 0.06A
< 0.4A
32.0VDC ± 3%
20.0VDC ± 3%
20.0VDC ± 3%
21.0VDC ± 3%
25.0VDC ± 3%
31.0VDC ± 3%
32.0VDC ± 3%
29.0VDC ± 3%
gpelectric.com | [page 13]