Nortel Communication Server 1000 Fundamentals page 106

Mini-carrier remote fundamentals
Hide thumbs Also See for Communication Server 1000:
Table of Contents

Advertisement

106 Maintenance
Figure 59
DISPLAY STATUS screen
Figure 60
DISPLAY STATUS DISTANT screen
3
The responses displayed on the screen show: the firmware
version, present time and date, individual carrier fault threshold
parameters, and the present status of each carrier link.
If a carrier-link mismatch exists, the status will display unequal
alarm levels across a mismatched link. To verify that carrier
links are connected correctly at both ends perform the tests in
"Verifying mini-carrier links at the remote site" (page
Display the alarm log by executing the DISPLAY ALARM (D
A), or DISPLAY ALARM DISTANT (D A D) commands. These
commands display the list of the most recent 100 alarms for the
near-end (D A) or distant-end (D A D) locations along with the
date and time that each alarm occurred. Both screens are similar
to
Figure 61 "DISPLAY ALARM (D A) screen" (page
Note: Invoking the D A and D A D commands display the
alarm log. To clear the alarm log, use the CLEAR ALARM LOG
(C A L) and CLEAR ALARM LOG DISTANT (C A L D)
commands.
Nortel Communication Server 1000
Mini-Carrier Remote Fundamentals
NN43001-557 04.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
96).
107).