Rinnai Timberflame IB30 Operating And Installation Instructions page 4

Table of Contents

Advertisement

CHECK DIMENSIONS OF FIREPLACE
Check dimensions of fireplace and if necessary bring
them to dimensions shown. Note. If the width of the
fireplace is less than 700mm then provision needs
to be made to run the gas supply outside of the
fireplace cavity. If the fireplace opening is larger than
the fire, a 100mm. wide decorative surround is
available from your local gas appliance retailer.
CHECK FLUEWAY
Check flueway is clear of obstructions.
Provide a firm, flat and sealed base for unit.
Sealed means no holes or openings in fireplace.
A rough base may affect the performance of this unit.
CHIMNEY INSPECTION
A. Improper chimney height.
B. Chimney Cap deterioration.
C. Creosote stains.
D. Blockage within flue.
E. Clearance to combustibles.
F. Soot / Creosote accumulation.
G. Structural deterioration.
H. Loose or broken bricks.
I. Smoke Pellet test. (Leakage)
SEALING THE INBUILT
INSTALLATION
Peel protective backing off the foam strips supplied
with the heater. Attach strips to rear of casing as
shown.
The strip is intended to form a seal between the
heater and fireplace. If an adequate seal cannot be
formed with this strip, another means of sealing must
be used (eg. non-combustible insulation), between
the fireplace and the heater body.
FLUEING
7
SEALING STRIPS