APPLIANCE GAS CONNECTION & COMMISSIONING
Once the engine has been installed and fixed to the building the gas and electricity can be connected. Some
installers elect to leave this until the decorating has been completed and the installation can be finished, remember
that the trim can not be attached until the wall lining is finished.
If commissioning is to be carried out after the decorating has been completed, leave a protective
cardboard cover taped to the front of the engine using a low-tack tape to prevent plaster dust and
debris from entering the engine and damaging the paint work.
CAUTION
Isolate the power and gas supplies before commencing work on the appliance.
Gas Connection
1.
Remove the open side and glass side front panels and strip all the protective plastic film from these items.
2.
Remove the protective plastic film from upper louvres on both sides.
3.
Remove the gas control shields (x2).
4.
Remove the pilot shield.
5.
Remove the burner assembly by removing the
two fixing screws in front of the burner and
pulling the tray forward and then upwards to
remove from the gas control.
6.
There may be aeration sleeves attached to the
venturi tubes on the back of the burner, take
care not to lose these, there is a chart on page
21 that shows which aeration sleeve should
be used depending on the gas and burner
media being used.
7.
After bending and flaring the gas supply pipe, purge the gas pipe and fix the gas control assembly back in
place and connect the gas.
8.
Replace and fix the burner assembly in place.
Gas Commissioning
240 VOLTS, RISK OF ELECTRICAL SHOCK!
When performing the commissioning, the appliance electrical power will need to be connected.
WARNING
Exercise CAUTION as there is potential for electric shock from the exposed wiring and circuitry.
DO NOT leave the appliance unattended when power is connected and the panels are removed.
Installation and commissioning must be carried out by an authorised person.
Wiring inside this appliance may be at 240V potential.
DO NOT test for gas escapes with an open flame.
GAS PRESSURES
Refer to the appliance data plate located inside the appliance on a swing tag for correct gas
NOTE
pressure settings.
To check and set burner pressures:
Using a suitable screw driver loosen the captive Appliance Test Point Pressure (ATPP) screw D and fit the
1.
manometer, (an electronic manometer is recommended). Refer images for ATPP location.
Remove the dust cap C from the regulator adjusting screws.
2.
3.
High Pressure Setting: Turn the appliance 'ON' and adjust to the highest setting, see "Remote Control
Operation" on page 6. Use a 10 mm spanner to turn nut A , lock screw B with appropriate screw driver
to prevent it turning. Turning nut A clockwise increases the outlet pressure whilst turning anti-clockwise
decreases the outlet pressure.
Rinnai
UPPER LOUVRES
PILOT SHIELD
BURNER ASSEMBLY
BURNER FIXING
GAS CONTROL FIXING
GAS CONTROL SHIELDS
20
GLASS SIDE FRONT PANEL
AIR DIVERTER
OPEN SIDE FRONT PANEL
RF1200TW OIM