Installation instructions, only for experts
Displaying the heater temperature in single-sensor mode
In single-sensor mode, the sauna control unit only displays the set temperature
as standard. The actual temperature is not displayed. Should the sauna control
unit display the temperature above the heater (F1) as an actual temperature in
single-sensor mode, it must be activated in the technician menu.
1. Open the technician menu (see page 29).
2. Activate the single-sensor mode (see page 29).
► The top display shows "SEnB".
► The bottom display shows "OFF".
3. Press the bottom knob.
► In the top display, "dISP" appears.
► In the bottom display, "SEt" appears.
("SEt" means that only the set temperature is displayed in single-sensor
mode.)
4. Turn the bottom knob to the left.
► In the bottom display, "SEnS" appears.
► The heater temperature (F1) is displayed as the actual temperature in the
single-sensor mode.
Decreasing the maximum temperature to 105 °C
The preset temperature can be set to between 30 °C and 110 °C as standard.
If you wish to decrease the maximum temperature from 110 °C to 105 °C, per-
form the following steps:
1. Open the technician menu (see 29).
2. Turn the top knob to the temperature symbol (position A – see point 9.2 on
page 34).
► The temperature symbol flashes.
► In the top display, "SEnB" appears.
3. Press the bottom knob once or twice until "t HI" appears in the top display.
► In the bottom display, "110" appears.
4. Turn the bottom knob to the left.
► In the bottom display, "105" appears.
► The maximum temperature was decreased from 110 °C to 105 °C.
p. 30/54