Settings In The Technician Menu - Harvia Sentiotec PRO-C3 Instructions For Installation And Use Manual

Sauna control unit
Hide thumbs Also See for Sentiotec PRO-C3:
Table of Contents

Advertisement

Installation instructions, only for experts

8.2. Settings in the technician menu

Opening the technician menu
Additional settings can be made in the technician menu. To access the technician
menu, perform the following steps:
1. Switch off the sauna control unit.
2. Press the bottom knob and the ON/OFF switch at the same time.
► In the top display, "SEtt" appears briefly.
► The two knobs flash.
The settings are saved as soon as you close the technician menu (see
Closing the technician menu on page 33).
Activating single-sensor mode
In single-sensor mode, the sauna control unit is operated with the heater sensor
with an excess temperature fuse (F1) only. The two-sensor mode is activated as
standard. If you wish to activate the single-sensor mode, perform the following
steps:
1. Open the technician menu (see 29).
2. Turn the top knob to the temperature symbol (position A – see point 9.2 on
page 34).
► The temperature symbol flashes.
► In the top display, "SEnB" appears.
► In the bottom display, "On" appears.
("On" means that the two-sensor mode is activated.)
3. Turn the bottom knob to the left.
► In the bottom display, "OFF" appears.
► The single-sensor mode is activated.
p. 29/54
EN

Advertisement

Table of Contents
loading

Table of Contents