Harvia Sentiotec PRO-C3 Instructions For Installation And Use Manual page 31

Sauna control unit
Hide thumbs Also See for Sentiotec PRO-C3:
Table of Contents

Advertisement

Installation instructions, only for experts
Activating simultaneous display of the temperature and humidity
To activate simultaneous display of the temperature and humidity, carry out the
following steps:
1. Open the technician menu (see 29).
2. Turn the top knob to the temperature symbol (position A – see point 9.2 on
page 34).
► The temperature symbol flashes.
► In the top display, "SEnB" appears.
3. Press the bottom knob several times until "ISt2" appears in the top display.
4. Turn the bottom knob to the left or right to activate or deactivate the function.
Activating evaporator single mode
With the factory setting, the evaporator can only be operated together with the
heating system. To operate the evaporator on its own without the heating system,
this function must be activated. To do so, perform the following steps:
1. Open the technician menu (see 29).
2. Turn the top knob to the humidity symbol (position B – see point 9.2 on
page 34).
► The humidity symbol flashes.
► In the top display, "SIn" appears.
► In the bottom display, "OFF" appears.
("OFF" means evaporator single mode is deactivated.)
3. Turn the bottom knob to the right.
► In the bottom display, "On" appears.
► Evaporator single mode is activated.
p. 31/54