Available commands are listed below.
I
Set the IPv6 address of the target of the ping.
Press "I." The command prompt changes to " Enter new target IPv6 address>."
Enter the IPv6 address.
N
Set the number of times of ping.
Press "N." The command prompt changes to "Enter new Request Times>." Enter
the number of times. Ping can be executed up to 10 times. Enter the number of
times between 1 and 10.
T
Set the time before timeout occurs.
Press "T." The command prompt changes to "Enter new Timeout Value>." Set the
time in seconds. Up to 5 seconds can be set. Enter the time between 1 to 5
seconds.
E
Execute the ping command. Or, clear the display.
Press "E." The command prompt changes to "Execute Ping or Clean before Ping
Data (E/C)>." Press "E" to execute ping. Press "C" to only clear the display.
S
Cancel the ping command.
Press "S" or "Ctrl+C" during the ping execution to cancel it.
Q
Return to the previous menu.
PN28240i Local Management System
Ping Execution -> IPv6 Ping Execution
Target IP Address:
Number of Requests:
Timeout Value:
=============== Result ===============
No. 1
No. 2
No. 3
No. 4
No. 5
No. 6
No. 7
Waiting for response...
-------------------------------- <COMMAND> -----------------------------------
Set Target [I]Pv6 Address
Set [N]umber of Requests
Set [T]imeout Value
>
S or Ctrl-C Stop ping function
Fig. 4-9-11 Display during Ping Execution
2001:1::1:201
10
3 Sec.
< 10 ms
< 10 ms
< 10 ms
< 10 ms
< 10 ms
< 10 ms
< 10 ms
[E]xecute Ping
[S]top Ping
[Q]uit to previous menu
247