Hpe 800W Flex Slot -48Vdc Hot Plug Low Halogen Power Supply - HPE ProLiant DL388 Gen10 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL388 Gen10:
Table of Contents

Advertisement

Specification
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power

HPE 800W Flex Slot -48VDC Hot Plug Low Halogen Power Supply

Specification
Input requirements
Rated input voltage
Rated input current
Rated input power (W)
Rated input power (BTUs per hour)
Power supply output
Rated steady-state power (W)
Maximum peak power (W)
Maximum peak power
WARNING: To reduce the risk of electric shock or energy hazards:
This equipment must be installed by trained service personnel.
Connect the equipment to a reliably grounded secondary circuit source. A secondary circuit has no
direct connection to a primary circuit and derives its power from a transformer, converter, or
equivalent isolation device.
The branch circuit overcurrent protection must be rated 27 A.
Value
2,964 at 200 VAC
2,951 at 230 VAC
2,936 at 277 VAC
800 W at 200 VAC to 277 VAC input
800 W at 200 VAC to 277 VAC input
Value
-40 VDC to -72 VDC
-48 VDC nominal input
24 A at -40 VDC input
19 A at -48 VDC input, nominal input
12.4 A at -72 VDC input
874 W at -40 VDC input
865 W at -48 VDC input, nominal input
854 W at -72 VDC input
2,983 at -40 VDC input
2,951 at -48 VDC input, nominal input
2,912 at -72 VDC input
800 W at -40 VDC to -72 VDC
800 W at -40 VDC to -72 VDC
800 W at 200 VAC to 277 VAC input
800 W at 380 VDC input
Specifications
161

Advertisement

Table of Contents
loading