Sat Tol
TX Pwr Zero
This field is used to select the Sat tolerance. When set to Narrow the Sat limit is
one of the three valid Sat tones
at 0 to 7000 Hz. When operating in noisy environments the narrow Sat limit may
not allow for correct measurements and the ability to alter the limit to encompass
a wider range provides for testing flexibility.
The :STOLerance command is used to control this field.
The query form (that is, :STOLerance?) can be used to query the current field
value.
Syntax
:STOLerance <'><NARROW/WIDE><'>
:STOLerance?
Example
OUTPUT 714;"CALLP:AMPS:STOL 'NARROW'"
OUTPUT 714;"CALLP:AMPS:STOL?"
ENTER 714;Stol_set$
The
function establishes a 0.0000 W reference for measuring RF
TX Pwr Zero
power at the RF IN/OUT port. The
screen and is programmed exactly as it is on its home screen.
ANALYZER
Analyzer" on page 177
RF power must not be applied while zeroing the power meter.
Chapter 8, Programming The Call Processing Subsystem
Programming The CALL CONFIGURE Screen
±
10Hz. When set to Wide the Sat limit is defined
TX Pwr Zero
for programming command syntax.
field is imported from the
See "RF
RF