HP 8920B Programmer's Manual page 513

Rf communications test set
Hide thumbs Also See for 8920B:
Table of Contents

Advertisement

ESN
RAND_A
This field is used to enter the electronic serial number (ESN) of the mobile station
into the Test Set. There are two methods which can be used to enter the
serial number can be captured by the Test Set through a registration order, or the
serial number can be entered as an 8-digit hexadecimal value directly into this
field.
To capture the electronic serial number through a registration , see
for further information.
page 503
To enter the serial number directly use the :ESNumber command.
The query form of the command (that is, :ESNumber?) can be used to determine
the current setting of the ESN field.
Syntax
:ESNumber <'><8 character hex value><'>
:ESNumber?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:ESN '12D4E678'"
OUTPUT 714:"CALLP:AMPS:AUTH:ESN?"
ENTER 714;Esn_val$
RAND_A is the 16 most significant bits of
hexadecimal value. The mobile station stores and uses the most recent version of
RAND_A in the authentication process. RAND_A is user definable.
The :RAND:A command is used to control this field.
The query form (that is, :RAND:A?) can be used to query the current field value.
Syntax
:RANDA
:RANDA?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:A '4F5A'"
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:A?"
ENTER 714;Rand_val$
Chapter 8, Programming The Call Processing Subsystem
Programming The AUTHENTICATION Screen
and is entered as a 4-digit
RAND
. The
ESN
"Register" on
513