To Turn Measurement Averaging ON and OFF.
commands to turn the averaging data function ON and OFF.
Syntax
:AVER age:STATe ON
:AVERage:STATe OFF
Example
OUTPUT 714;"MEAS:AFR:DISTN:AVER:STAT ON"
This turns the AVG Data Function ON for the Audio Frequency
Analyzer Distortion measurement.
To Query the Measurement Averaging State.
commands to query the current state of the averaging data function. The returned
value is either: 0 (OFF) or 1 (ON).
Syntax
:AVERage:STAT?
Example
OUTPUT 714;"MEAS:AFR:DISTN:AVER:STAT?"
ENTER 714;State_on_off ! 1 = ON, 0 = OFF
This queries the state of the AVG Data Function for the Audio
Frequency Analyzer Distortion measurement.
Equivalent Front-Panel Key Commands
Use the :AVERage:STATe
Use the :AVERage:STAT?