Parameterisation
Byte
Bit
Process input data
0
7 ... 1
0
Process output data
0
7 ... 1
0
Tab. 42: Process data of the soft start valves
Process data of the pilot air switching valves without M12 connection
The process data belong to the following type codes:
– VSVA-BT-M32CS2-MYE-A2-1T5L-PA
– VSVA-BT-M32CS1-MYE-A2-1T5L-PA
– VSVA-BT-M32CS2-MS-A2-1T5L-PA
– VSVA-BT-M32CS1-MS-A2-1T5L-PA
Byte
Bit
Process input data
0
7 ... 1
0
Process output data
0
7 ... 1
0
Tab. 43: Process data of the pilot air switching valves without M12 connection
Process data of the pilot air switching valves with M12 connection
The process data belong to the following type codes:
– VSVA-BT-M32CS2-MYE-A2-1T1L-PZ
– VSVA-BT-M32CS1-MYE-A2-1T1L-PZ
– VSVA-BT-M32CS2-MS-A2-1T1L-PZ
– VSVA-BT-M32CS1-MS-A2-1T1L-PZ
No process input data available
68
Description
reserved
– 0: duct (1) is pressurised
– 1: duct (1) is exhausted
reserved
– 0: valve switched off
– 1: valve switched on
Description
reserved
– 0: duct (14) is pressurised
– 1: duct (14) is exhausted
reserved
– 0: valve switched off
– 1: valve switched on
Festo — VTSA-F-CB — 2021-06a