Smart Grid Settings - Bosch HPC 400 Installation Instructions For Contractors

User interface ems 2
Table of Contents

Advertisement

Service menu
BOSCH
LP
at brine
circuit
alarm
Off
A low pressure alarm
is
available
for the
brine
irrespective
of
L
-
-2-"
Off
Flow
temperature switch
,
A low
pressure
alarm
is
available for the brine pump dependent on open and closed contact.
- -
- -
~--
- -
No
fault display
is
recorded for a
flow controller.
I
Block
compressor
On
- -
Off
Dependent on open and
closed contact. a
fault
is
present at the flow
controller.
Compressor
operation is enabled
irrespective
of open and closed contact.
On
Compressor
operation
is
blocked dependent on open and
closed
contact.
Block DHW operation
I
Off
DHW heating is enabled
irrespective
of open and closed contact.
On
DHW heating
is
blocked dependent on open and closed
contact.
Off
Heating mode
is
enabled irrespective of open and closed
contact.
I
Block heating mode
- - - -
- -
. -
-
-
-
- -
-
On
Heating mode
is
blocked dependent on open
and closed
contact.
Block
cooling
operation
Off
Cooling mode
is
enabled
irrespective
of open and closed
contact.
On
Cooling mode is blocked dependent on open and closed contact.
- - -
- - -
I
- -
Overheat. protection HCl
.-
IOn
Off
No overheating protection
for heating/cooling circuit
1.
I
,
Thermostat for
overheating protection for heating/cooling circuit 1
is
connected to external
connection
1
...
3.
If
the thermostat switches,
the
heat pump stops heating mode and switches the heating/cooling circuit pump
off.
EVU blocking timel on
Off
Constant
power supply for the
compressor
and auxiliary heater from the energy supplier.
[On
1
-
- -
~
-
-
-
-
-
-
- '-'
Power supply for the compressor and auxiliary heater
is
switched
off
by the energy
supplier.
EVU blocking time2 on
Off
Constant power supply for the compressor and auxiliary
heater
from the energy supplier.
On
Power supply for the compressor is switched off by the energy supplier. The auxiliary heater remains in
operation.
ESC blocking time3 on
Off
Constant
power
supply
for the
compressor
and auxiliary heater from the energy supplier.
On
-:--:-
-
Block additional heater
Off
Auxiliary heater operation
is
enabled dependent on open and closed c{)ntact.
.
On
__
t __ _
Auxiliary heater operation
is
blocked dependent on open and closed
contact._
I
Photovoltaic system
Off
No output
can
be extracted from the photovoltaic
(PV)
system.
IOn
Output
can
be extracted from the photovoltaic (PV)
system
dependent on open and
closed
contact.
Table
16
Settings for the external connections of the heat pump
6.1.4
Smart grid settings
This menu allows you to set whether the energy available in the smart
grid should be used for heating or DHW heating.
Heating
The energy
available
in
the
"smart
grid" is used to
increase
the required
room temperature in optimised operation and in the heating system
Table
17
Smart grid settings (heating)
DHW
automatic mode by the value that has been set
here.
The room
temperature is always
limited
to a maximum of 30
DC.
-
The DHW
is
heated to the temperature setforthe
DHW
operating
mode.
It doesn't matter which operating mode
is
active for DHW
heating.
The DHW temperature
is
not raised if the holiday program is
active.
Table 18 Smart grid settings (DHW)
Buffer cylinder
If a buffer cylinder is installed and all heating circuits have mixing
devices, the buffer cylinder will be heated to the maximum temperature
of the heat pump when smart grid energy usage is activated.
14
HPe 100 - 6
no
821 772 (2017;07)