Priority Heating Circuit 1; Settings For Heating Circuit 1 - Bosch HPC 400 Installation Instructions For Contractors

User interface ems 2
Table of Contents

Advertisement

Service menu
6.3.2
Priority heating circuit 1
BOSCH
In the default setting any changes in the outside
temperature have an effect after a delay of three hours at
the latest on the calculation of the weather-
compensated control.
~
To view the course of the outside temperature
of
the
last 2 days; open the
Info
>
Room and outdoor
temp.
>
Outdoor temp. curve
menu
This menu item allows the other heating circuits to be restricted via
heating circuit
L
If a heat requirement comes from heating circuit
1
and
others simultaneously. this
setting
is used to determine whether the
heat requirement forthe other heating circuits is always met
Depending
on the setting. the heat requirement forthe other heating circuits
is
only
met if heating circuit
1
is supplied accordingly_
Priority heating circuit 1
No
Heating circuit 1
is
the primary heating circuit. Heat requirements for other circuits are only handled if heating
circuit
1
1
has a heat requirement. The flow temperature required for heating
circuit
1 limits the flow temperature of the other
heating
circuits_
Example:
HK1 requires 50
'C.
HK2 requires 55 "C. but receives a maximum of 50'C (in line with
HK1).
HK3
requires
45'C and receives 45'C
(notlimited
by
HK1).
Unmixed heating circuit 1 will be forced to run when any other circuit requests heat. So heating
circuit
1 might
have
a
higher temperature then
wanted.
Table
26
Settings in the
Priority heating
circuit
1
menu
6.3.3
Settings for heating circuit 1
...
4
Settings for the individual heating/cooling circuits can be made in this
menu.
For
example.
you can set which heating system is
installed
for the
selected heating/cooling circuit. In addition it can be set whether a
remote control is available and which control type is used. It is also
possible to
optimise
the heating curves of the heating/cooling circuits.
NonCE:
Risk
of damaging the screed!
~
If an underfloor heating system is used. the
max.
flow
temperature recommended by the manufacturer of
the system should be observed.
At the module
User interface
CR10H
A heating/cooling circuit
is
not
installed.
If no heating/cooling circuit
is
installed. the heat source
is
only
used for DHW
heating.
Electrical assemblies and components of the selected heating/cooling circuit are directly connected to the
I
heat source (only available with heating circuit
1).
Electrical assemblies and components of the selected heating/cooling circuit are connected to an MM 100
module.
CR 10 is installed as a remote control for the
heating/cooling circuit. This allows
compensated control
influenced
by room
temperature.
=-:--::-----,:------:--1
CR 10
is installed
as a remote control for the selected heating/cooling
circuit.
This allows for
weather-
compensated control influenced by room temperature.
~------------~------~------~----~--~----~---
ext. room
temp.
sensor
Yes
An additional room temperature sensor is
installed (no
CR 10lCR 10
H).
This allows for
weather-
No
- - - - I I
Heating system heat circ. 1
Radiator
I
i
Convector heater
Circuit function
I
Ctrl
type h.
clrc.
1
l
_ _
r
Max.
flow temperature
Set heating
curve
IUnderfioor
Heating
I
Cooling
Heating and cooling
0
Outdoor temp.
compensated
Outside
temp.
with low end
30
...
75
...
85'C
(radiator/convector)
30
...
48
...
60'C
(underfloor heating system)
compensated control
influenced
by the room
temperature.
No additional room temperature sensor is
installed.
- - - - -
- - - -
Factory default of the heating curve according to heating
type, e.g.
curvature and design temperature
The selected heating/cooling
circuit is
only used to provide heating in the corresponding
room.
The selected heating/cooling circuit
is
only used to provide
cooling
in the corresponding
room.
- -
- -
The selected heating/cooling circuit
is
only used to provide heating and cooling in the corresponding
room.
Further information on the
control
type for the selected heating
CIrCUit
(
~
Control types for the heating
system, page 20)
Maximum flow temperature
I
Fine adjustment
of
the heating curve that is preset via the heating system
(~
Set the heating system and
heating
curve
for weather-compensated
control,
page 20)
----~~--~----------~
Table
27
Settings in menu heating/cooling circuit
1
...
4