Bosch HPC 400 Installation Instructions For Contractors page 19

User interface ems 2
Table of Contents

Advertisement

(§)
BOSCH
Service menu
The heating system operates
independent
from the the adjusted outside temperature in the active
I
I
r
d (-? H t
t tl b I
rt
'
t 'd t
t
22)
opera mg rna e
ea cons an y e ow a ce am au
Sl
e empera ure. page
I
-
30
...
10 ·C
I
If the adjusted outside temperature falls below the value set here. the heating system automatically
I
changes from the setback mode into the heating mode (-? Heat constantly below a certain outside
I
I
I
temperature. page 22)
.
Frost protection
I
.
O~QQI
Note:
To ensure frost protection for the entire heating system. set outside temperature-dependent frost
L
protection.
This setting is independent of the set control
type.
~m
and outdoor
temp.
Frost protection is deactivated/activated on the basis of the temperature
Room temperature
selected here
{-?
Frost protection limit temperature (outside temperature threshold), page 23)
Room and outdoor
temp.
I
Off
Frost protection off
I
--
- - -
~
-
- -
-
c-
-
- - -
-
-
-
- - -
Frost prot. limit
temp.
-
20
...
5
...
10·C
-?
Frost protection limit temperature (outside temperature threshold)
.
page 23
(outside temperature
I
Z.
threshold)
r-:-:- -
-
- -
-
- -
- - -
- -
--
Heating/Cooling
Off
(Ot+!j
{q~,.,J ~
... ....,-
- - -
-
-
- - - - -
Automatic mode
The heat pump automatically switches between heating mode and cooling mode subject to the outside
I
temperature.
I
Constant heating
.
The heat pump runs solely in heating
mode.
Constant cooling
The heat pump runs solely in cooling
mode.
T--
- -
- -
- - - - - - -
- -
- -
- -
-
Heating mode from
10
...
17
...
30·C
If the outside temperature falls below the value set here. heating mode is
activated.
Cooling mode from
- 20
...
28
..
.
35"C
If the outside temperature exceeds the value set here. cooling mode is activated.
Heating direct start limit
1
...
1
...
10 K
If the outside temperature falls below the heating mode from temperature (setting value for Heating mode
from) by the value set
here.
heating mode is activated immediately.
- - -
r-
-
-
-
~
- -
- -
- -
Cooling switch-off delay
1...
4
...
4Sh
Switch-off delay for cooling
mode.
Cooling switch-on delay
1...
8
..
. 4Sh
Switch-on delay for cooling
mode.
Heating switch-off delay
r-
1
...
1...4Sh
Switch-off delay for heating
mode.
1 - - - - - - -
- - - - -
- - - - - -
- -
- -
- -
- -
Heating switch-on delay
1...
4
...
4Sh
Switch-on delay for heating mode.
Room temp. switch.
diff.
-5
...
2
...
5K
If the measured room temperature exceeds the set room temperature by the amount set here. cooling
mode is activated
(e.g.
for
2
K: set room temperature
=
23
·C;
measured room temperature
=
25·C -
cooling mode is activated)
Dew paint
temp.
diff.
I
2 ...
5
...
10 K
Defines the safety margin to the calculated dew point. As
a
result. the set flow temperature is above the
calculated dew point by at least the value set
here.
Min.
set flow temperature
10
..
.
10
...
35"C
If a humidity sensor
is
installed for the heating/cooling circuit: minimum set flow temperature
10
...
17
...
35·C
If a humidity sensor is not installed for the heating/cooling circuit: minimum set flow temperature
Mixer
Yes
Selected heating/cooling circuit with mixing valve
No
Selected heating/cooling circuit without mixing valve
Mixer runtime
Mixing valve runtime
in
the selected heating/cooling circuit
Shown in standard display
Yes
The selected heating/cooling circuit is visible in the standard
display.
No
The selected heating/cooling circuit is not visible
in
the standard
display.
Table 27 Settings in menu heating/cooling circuit 1
...
4
HPC400-6720821772(2017/07)
19