6.1.5
Photovoltaic
system settings
This menu allows you to set whether the energy supplied by the
photovoltaic (PV) system should be used for DHW heating or
heating.
The energy supplied by the PV system is used to increase the required
room temperature in optimised operation and in the heating system
automatic mode by the value that has been set here. The room
temperature is always limited to a maximum of 30
DC.
Service menu
The DHW is heated to the temperature set for the
DHW
operating
mode.
It doesn't matter which operating mode is active for DHW
heating.
The DHW temperature is not raised if the holiday program is
active.
If a buffer cylinder is installed and all heating circuits have mixing
devices,
the buffer cylinder will be heated to the maximum temperature
of the heat pump when photovoltaic system is
activated.
Menu item
Adjustment range
description
I
Heating
.f>.ea
~
_
--!.
DHWpeak
No
0
...
5 K
Yes
Table 19 Photo voltaic system settings
6.2
Auxiliary heater settings
Settings for an auxiliary heater can be made in this
menu.
Auxiliary
heating is required if the heat pump is not able to supply enough heat,
e.g.
in winter. or if requirements for DHW cannot be met quickly enough.
6.2.1
General settings for an auxiliary heater
Settings for an auxiliary heater that are available for all types of auxiliary
heater can be made in this menu. For example. you can set how auxiliary
heating is to be performed and when the auxiliary heater should be
used.
Allows the temperature
In
the system to be raised by the set
value.
Raising the temperature in the DHW cylinder is
enabled.
Raising the temperature in the DHW cylinder is not
enabled.
Add.
electric heater in
series
1 )
J
A
n electric adittional heater is connected in series with the heat
pump.
Single energy
source~
~
I
Add.
heater with mixer only
An auxiliary heater
(gas. oil.
electric) is connected in parallel with the heat
pump.
The flow of heat from the
Dual mode alternative
2
)
---;
auxiliary heater is conveyed to the heating system via a mixing
valve.
The heat pump and auxiliary heater
work
exclusively. I.e.
either the heat pump or the auxiliary heater is running. but not
both.
I
Add.
heater with mixer in
I
An auxiliary heater (gas.
oil.
electric) is connected in parallel with the heat
pump.
The flow of heat from the
I
parallel
1
)
auxiliary heater is conveyed to the heating system via a mixing
valve.
The heat pump and auxiliary heater
"'-
D
-u-:'
al-m -od
" -
e
-
p
-a-
r
a-:-
lIe
""'
1
2
n-)
- - - 1
can work in parallel.
I.e.
the auxiliary heater provides an additional flow of heat when the required
r-:-~-:-:----c-:-­
Additional heater on delay
,
Mode after EVU block
Hybrid
0
...
900K
·
min
Comfort
temperature is unable to be supplied by the heat pump
alone.
-
- -
-
The heat pump is part of a hybrid
system.
The auxiliary heater switches on after a
delay.
During this
time.
the heat pump only heats with the
compressor.
When all the conditions for operating the auxiliary heater have been met. the auxiliary heater can start
operation immediately following an energy supplier
block.
I
ECO
Even once all the conditions for operating the auxiliary heater have been
met.
the auxiliary heater can only
start operation following an energy supplier block after a delay period has
passed.
I
~~~~--~----------~-------r----~~
I
Additional heater only
Yes
Only the auxiliary heater is used to
produce_
h_
e a
_
t. The
co_
m p
_
ressor is s
_
w'
_
l tched
off_
.
_
No
The heat pump and auxiliary heater are available for producing heat.
Switch off
add.
heater
Yes
Heating is generally only provided by the heat
pump.
The auxiliary heater is only switched on during extra
No
Max.
additional heater
temp.
Table 20 General settings for an auxiliary heater
1) Not available if Germany is set as the
country.
2) Only available if Germany is set as the
country.
Maximum auxiliary heater
temperature
If the heat pump is not running at its full output (maximum possible
temperature), the auxiliary heater does not need to be
operated.
It is
DHW.
thermal disinfection or alarm
operation.
The heat pump and auxiliary heater are available for producing heat.
~
Chapter "Maximum auxiliary heater
temperature"
possible to set the temperature atwhich the auxiliary heater switches off
here.
pump is below
maximum heat pump temperature that is set here. the auxiliary heater is
off.
If the temperature of the heat pump is below the maximum heat pump temperature that is set
here.
the auxiliary heater operates
I
with a limited output.
L
Table 21 Settings for the pumps in the heat pump