Working with the main menu
5
Working with the main menu
I
Main
menu
1
~
~
Hli
Heating/Cooling
I
ffi-
H
Extra hot
water
J
H
Operating
mode
I
--I
Start now
I
H
Temperature
settings
I
Hcancel
J
HHeating
I
H
Temperature
I
HSetbacJ<
J
YOuration
J
YCooling
I
H
Thermal disinfection
I
---{TIme
program
I
HStart
J
H Activate
time program
I
HStartnow
I
H My
time
program
1
J
Hcancel
J
H Reset
prog.
I
H
Temperature
J
H My
time program 2
J
--I
Day
J
H Reset
prog.
I
HTimeofday
J
H Rename
heating circuit
J
Y
Max.
period
J
Y Rename time program
I
H DHW
alternating operation
I
---{
Sum./wint. changeover
J
--I
DHW
a~ernating
operation
J
H Heating/Cooling
I
--I
OHW
priority for
J
H
Heating
mode
from
J
'-i
Prioritise heating for
J
Y
Cooling mode
from
J
Y
Circulation
J11
H
OHW
a~ernating
operation
I
H
Operating mode
J
H OHW alternating
operation
J
H
Start frequency
J
H OHW priority
for
I
Y
My
OHW
circJtn time
prog.
J
Y Prioritise heating for
J
H
..
Pool
J
--f
Priority
heating
circuit
1
I
H
Activate pool heating
I
H':'"
OHW
I
H Pool temperature
J
H
Operating
mode
I
Y Allow additional heat
in pool
I
H
Time
program
H[
Device
J
~
My
OHW time
program
I
--I
Time
program additional
I
Resetprog.
H
TIme
program
Activate
I
~
H My
time
program
J
~
H
Reset
time
program
I
Y Time
program
min.
outdoor
J
Y
Low·noise
operation
I
~Low.noise
operation
J
Min.outdoortemperature
J
YE
Fig.
3
Menu structure of the mam menu
1)
Not available jf Sweden or Finland is
set
as the country
(for
the
contractor
only)
.
9
BOSCH
HO
Holiday
J
H fill
Hybrid system
I
4
Energy:price ratio
I
H
Smart
Grid
I
HHeating
I
-e
Selectable
peak
Forced peak
I
YOHW
4
Selectable peak
J
H
~
PVsystem
I
WHeatingpeak
J
OHWpeak
I
'-i'"
Settings
I
---f
Language
I
-{TIme
format
I
---f
TIme of
day
I
HOatefoonat
I
HOate
I
H
Autom.
time changeover
HOisplay
contrast
I
H
Warning
sound
I
H Room
temp. sen. adj.
I
H
OHW temperature
I
H Time
correction
J
H
Standard
display
I
H
Internet password
LfReset
I
WResetsettings
4
Reset
seNice messages
I
6720811136·101.30
14
HPC 400 6720821983 (2017107)
9
BOSCH
Working with the main menu
5.1
Main menu summary
~
Turn the selector to select the heating circuit for which the
settings are being
changed.
If two or more heating/cooling circuits are installed in the
system, an additional selection must be made
in
some
menus:
~
Press the selector to display the menu.
Change the operating mode, room temperatures and time program
for
the heating system
permanently.
I
Operating
mode
J
Select the heating operating
mode,
based on a time program or
optimised.
4
I
I
T_~
S"""""i,,,, ~m l.m,."M~ ""to'" ... ~i""
"' ' ' "
I'M"'"
i" Ih"im.
,,,,,,,m,
1
16
I
I
settln:::
gs
_
_ _ _ ~,
e.g.
with heating and setback mode or
cooling
mod-=--
,
Time program
Switch between heating and setback mode at defined times of day and on defined days of
16
f
Sum./wint.
changeover
DHW
alternating
I
operation
Priority heating
circuit 1
~DHW
Operating
mode
Time prOIram
the week (automatic
mode).
Separate time programs can be used for DHW and
circulation.
Heating circuits and time programs are' renamed In thiS
menu.
Switch automatically between summer mode (heating off or
cooling),
winter mode (heating
20
on) or automatic mode (sometimes
subject
to outside temperature).
If DHW alternating operation is
activated,
the heat generated by
- ""'
th-e-he
-
a -t
-
p u -m -p
-
is
us~
e
20
alternately for heating and DHW
heating.
Heating circuit
1
determines how the
system
behaves. If there IS no heat reqUirement for
20
heating
circuit
1, no heat requirements for other circuits are handled either.
Change the water temperatures and time program for
DHW
heating
permanently.
20
Select the DHW heating operating mode,
e.g.
based on a time program or always
on.
21
Switch between DHW, reduced DHW heating and no DHW heating operating modes at
defined times of day and on defined days of the week (automatic mode).
21
Extra hot
water
Change the temperature and duration of the extra DHW function.
22
122
23
Thermal disinfection
Heat up DHW to kill off
pathogens.
--- ----
DHW
alternati"l
If DHW alternating operation is activated, the heat generated by the heat pump is used
operation
alternately for heating and DHW
heating.
I
I
Set time program for DHW circulation so that DHW is available without delay at
the
draw·off 23
Circulation
points.
I
;. Pool
Settings for operating a heated swimming pool.
--t
241
Device
Settings for operating an auxiliary heater (electric/gas/oil/solid fuel)
.
24
Time program
The time program for the auxiliary heater specifies the periods during which additional heat
24
additional heat
I
can be generated by the
auxiliary
heater.
~
o
HOlida-
y
- -
Settings for operating the
system
during prolonged periods of absence (holiday program).
25
I) Hybrid system
-
Set the energy/price ratio.
28
~
Smart Grid
Use energy from the
"smart
grid" for heating or DHW heating.
29
Heating
DHW
!.-
PV system
Temperature
setting
for forced or
selectable
peak
-----
-~--------------------
Switch selectable peak on and off
Use energy generated by the photovoltaic system for heating or DHW heating.
29
29
29
Change general settings such as
time,
date. display
contrast,
etc. or restore settings
saved
30
by the
contractor.
___
___
l
.,. Settings
low-noise operation
Settings for reducing noise emissions from the heat pump
31
Table
9
Main menu summary
5.2
Adapting settings for heating system
automatic mode
Menu:
Heatina/Cooling
HPC400 6720821983 (2017107)
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents