5) IP1 (PoE) Installation Wiring (Continued)
B
Hinge Installation
Order of installation may vary. Refer to appropriate sections for instructions.
Hinge-side harness connectors:
4-pin male Molex connector
6-pin male Molex connector with ground wire
Lock-side harness connectors:
Ring terminal
(2) 4-pin connectors:
4-pin Molex connector
4-pin connector
Notes:
Connectors go on only one way. They cannot be plugged to incorrect position.
Do not force and do not offset connectors.
Be sure they are completely seated (flush).
4-pin F
6-pin F
PoE Hinge (Patent Pending)
C
Door Harness Installaion
Order of installation may vary. Refer to appropriate sections for
instructions.
1. Prop door open.
2. Tape the two lock-side 4-pin connectors to the ring terminal.
3. Using the ring terminal, carefully fish the assembly through the
door channel to the lock.
4. Remove tape from ring terminal and door harness connectors.
Hinge-side harness connectors:
4-pin male Molex connector
6-pin male Molex connector with ground wire
Lock-side harness connectors:
Ring terminal
(2) 4-pin connectors:
4-pin Molex connector
4-pin connector
Notes:
Connectors go on only one way. They cannot be plugged to
incorrect position.
Do not force and do not offset connectors.
Be sure they are completely seated (flush).
B
4-pin M
4-pin F
6-pin F
6-pin M
Terminal Secured
C
Drain Wire
Cable
: CAT 5e,
26 AWG stranded,
shielded, 100ohm
15
ASSA ABLOY
D
PoE Lock
JST
4-Pin
4-Pin
Molex
Ground
Ring
to Lock Mounting Plate