H – Holding time
The holding time indicates how long an object is fired at the holding temperature. In multi-stage programs
H1, H2, H3, H4 or H5, depending on the stage.
Value range:
H1: 00 – 60:00 (mm:ss)
H2: 00 – 60:00 (mm:ss)
H3: 00 – 30:00 (mm:ss)
H4: 00 – 30:00 (mm:ss)
H5: 00 – 30:00 (mm:ss)
Vacuum on
The parameter defines the temperature at which the vacuum is activated.
Value range °C: Off or 1-1200°C; Value range °F: Off or 34-2192 °F
Vacuum off
The parameter defines the temperature at which the vacuum is deactivated.
• Holding time without vacuum: If V2 is set lower than the holding temperature, the vacuum is ended
before the holding time.
• Holding time with vacuum: If V2 corresponds to the holding temperature, the vacuum is maintained
during the entire holding time.
• Long-term cooling with vacuum: If V2 is set higher than the holding temperature, the vacuum is
maintained during long-term cooling.
Value range °C: Off or 1-1200°C; Value range °F: Off or 34-2192 °F
Predrying
Four predefined predrying programs are available:
• Off
• Crystallization (crystallization alone or in conjunction with the glaze spray)
• Glaze (spray or paste)
• ZrO
wet (for wet-machined zirconia)
2
Predrying is always required for crystallization programs.

2.2.2.6 Adjustable parameters in the Options menu

In addition to the parameters shown in the firing curve, several other options are available that can be activated by pressing
the [Options] button. Active options are shown with icons in the grid next to the Options button.
The following firing program options are available:
Program write-protection
If the program write-protection is activated, the program parameters and program options cannot be
changed. This is to prevent accidental changes to the program.
Setting option: On/Off
Quick opening
If the option "Quick opening of the furnace head" is activated, the furnace head opens at maximum
speed at the end of the program.
Setting option: On/Off