Adjustable Parameters And Possible Value Ranges - Ivoclar Vivadent Programat EP 5000 Operating Instructions Manual

Table of Contents

Advertisement

a) Standard programs for Ivoclar Vivadent
materials
– IPS d.SIGN
– IPS InLine
– IPS Empress Esthetic
– IPS e.max Press
– IPS e.max Ceram
– Various Add-On materials
When the furnace is delivered ex
works, the standard programs already
contain the recommended material
parameter settings. Moreover, the
programs are write-protected. Please
refer to the respective list of parameters
in Chapter 10.
However, the parameters can be changed and
overwritten at any time, if the programs are to be
used for other purposes. Therefore, these
programs are also available as free programs.
b) Free programs
– Free, individually adjustable programs
The programs are designed in such a way that
they can be either used as conventional, one-stage
programs or as two-stage programs, if required.
The mode can be changed via the symbol (one- or
two-stage program) by using the + or – key.
c) Special programs
Various test programs are available. Please refer
to chapter 5.5.5 Special programs.

5.4 Adjustable parameters and possible value ranges

Symbol
Parameter
P
Program number P
B
Stand-by temperature
S
Closing time (min : sec)
Pre-vaccum (min : sec)
Temperature increase rate
T
Holding temperature
H
Holding time (min : sec)
V1
Vacuum on
V2
Vacuum off
L
Long-term cooling
tL
Cooling temperature rate
t2À
Temperature increase rate
2
stage
nd
T2
Holding temperature 2
H2
Holding time 2
nd
stage (min : sec)
V1 2
Vacuum on temp. 2
V2 2
Vacuum off temp. 2
V
Pre-drying temp.
T
V
Pre-drying holding time (min : sec)
H
H
Holding time Vacuum (min : sec)
V
Pre-drying temperature
Pre-drying time
Automatic plausibility check
The furnace is equipped with an automatic plausibility check function. The parameters
(e.g. T 960 but L 1000) are checked upon each program start. In case of contradictory
parameter combinations, the program stops automatically and the respective error
number is indicated.
List of parameters
In this screen, the arrow keys can be used to navigate within the list (including
program number). An active numeric value can be edited using the – / + keys or the
numeric keypad.
An active symbol parameter can only be changed using the – / + keys.
List of parameters – Two-stage program
20
Value range
001–200
100–700 °C
00:18–30:00
01:00–05:00
10–140 °C/min
100–1200 °C
00.01–60:00
0 or 1–1200 °C
0 or 1–1200 °C
0 or 50–1200 °C
0 or 1–50 °C
10–140 °C/min
nd
stage
100–1200 °C
00.01–60:00
nd
stage
0 or 1–1200 °C
nd
stage
0 or 1–1200 °C
100–700 °C
00:00–60:00
00:01–60:00
0 or 100–700 °C
00:00-60:00
Value range
212–1292 °F
18–252 °F/min
212–2192 °F
0 or 34–2192 °F
0 or 34–2192 °F
0 or 122–2192 °F
0 or 2–90 °F/min
18–252 °F/min
212–2192 °F
0 or 34–2192 °F
0 or 34–2192 °F
212–1292 °F
0 or 212–1292 °F