S82J

Specifications

Ratings/Characteristics
Item
Efficiency (typical)
Input
Voltage
100 VAC
input
200 VAC
input
Frequency
Current
100 VAC
(see note
(see note
input
2)
2)
200 VAC
input
Leakage
100 VAC
current
current
input
(see note
(
t
200 VAC
2)
input
Inrush
100 VAC
current
input
(25 C,
(25 C,
cold start)
200 VAC
(see note
input
2)
Noise filter
Output
Voltage adjustment
(see note
(see note
range
3)
3)
Ripple (see note 2)
Input
100 VAC
variation
variation
input
influence
i fl
200 VAC
input
Load variation
influence
Temperature variation
influence
Rise time
Hold time (see note 2)
Additional
Overload protection
function
Overvoltage protection
(see note 5)
Overheat protection
Protection-On alarm
indicator
Parallel operation
Series operation
100 VAC input/200 VAC input
10 W
25 W
50 W
(5, 12 V)
67% min.
100 VAC (85 to 132 VAC), 110 to 170 VDC
(see note 1)
200 VAC (170 to 264 VAC)
50/60 Hz (47 to 450 Hz)
0.35 A
0.8 A
1.4 A
max.
max.
max.
0.3 A
0.6 A
0.8 A
max.
max.
max.
0.5 mA max.
1 mA max.
25 A max.
50 A max.
Yes
10% (adjustable with variable resistor (V.ADJ))
2% (p-p) max.
0.4% max. (at 85 to 132 VAC input, 100% load)
0.4% max. (at 170 to 264 VAC input, 100% load)
0.8% max. (with rated input, 10% to 100% load)
0.05%/ C max. (with rated input and output)
200 ms max. (up to 90% of output voltage at
rated input and output)
20 ms min.
105% min. of rated load current, inverted L drop type, automatic reset (For
the 600-W model, the circuit will be shut OFF when the overload exceeds
5 3s. Protection-ON alarm indicator lit. (see note 4)).
No
No
No
No
No
100 or 200 VAC
(selectable)
100 W (5,
300 W
600 W
12, 15 V)
76% min.
82% min.
100 (85 to 132) or 200
(170 to 253) VAC
(selectable)
2.5 A
8 A max.
14 A max.
1.4 A
4 A max.
7 A max.
30 A max.
60 A max.
0.4% max.
300 ms max. (up to
90% of output voltage
at rated input and
output)
Yes (5-V
Yes, protection-ON
output
alarm indicator lit.
models
only)
Yes,
protection
-ON
alarm
indicator
lit (see
note 4)
Yes (color, red)
Yes, 5 units max.
Yes
S82J
100 to 240 VAC input
100 or 200
VAC
(selected
automatic
ally)
50 W
100 W
150 W
(24 V)
(24 V)
77% min.
83% min.
82% min.
100 to 240 VAC (85 to
100 (85 to
264 VAC)
132) or 200
(170 to
264) VAC
264) VAC
(selected
automatical
ly)
1.4 A
2.5 A
3.5 A max.
max.
max.
0.8 A
1.5 A
2.1 A max.
max.
max.
25 A max.
50 A max.
500 ms min. (up to 90% of output
voltage at rated input and output)
105 to 160% of rated
105% min.
load current, inverted L
of rated
drop/Intermittent
load
operation type,
current,
automatic reset)
inverted L
drop type,
automatic
reset
No
Yes
No
No
No
No
5