2 POTS, 2 GigE ONT Installation and Maintenance Practice

Fiber Drop Cable Installation

A fiber connection is required between the inner ONT enclosure and the fiber termination
point installed in the outer enclosure. This may be achieved by using the provided fiber patch
cord. Remove the dust cover from one end of the fiber patch cord and attach it to the incoming
fiber drop cable at either the Optitap Adaptor or the SC/PC bulk head (see
The fiber drop cable can be dressed around the fiber management feature. The loose end of
the patch cord should be left with the dust cover on. It will be connected to the inner module
after it is installed.
OpTicap
Adaptor
SC
Bulkhead
Loose end of
fiber patch cord
34

Figure 22. Fiber Patch Cord Installation

Figure
22).
Dress excess fiber drop
cable around fiber
management feature
61187602G2-5A