ADTRAN QFO-C Installation And Maintenance Manual
ADTRAN QFO-C Installation And Maintenance Manual

ADTRAN QFO-C Installation And Maintenance Manual

Adtran network device brochure
Table of Contents

Advertisement

Quick Links

CONTENTS
1. GENERAL ............................................................................ 1
2. INSTALLATION .................................................................. 2
3. OPERATION ........................................................................ 5
4. MAINTENANCE ................................................................ 28
5. WARRANTY AND CUSTOMER SERVICE ................... 28
FIGURES
Figure 1.
Total Access QFO-C .............................................. 1
Figure 2.
Total Access 3000 CO Mounting Shelf ................. 5
Figure 3.
Fiber Optic Receiver Cabling ................................. 6
Figure 4.
QFO-C FCD Menu Tree ....................................... 10
Figure 5.
Fiber Main Menu Screen ...................................... 12
Figure 6.
QFO-C Configuration Screen ............................... 12
Figure 7.
Provisioning Screen .............................................. 13
Figure 8.
Service State Screen ............................................. 13
Figure 9.
Port Service Status Screen .................................... 14
Figure 10.
Provisioning of All Ports Screen .......................... 14
Figure 11.
DSX Equalization Screen ..................................... 15
Figure 12.
Loopback Timeout Screen .................................... 15
Figure 13.
AIS to DSX (Loss of T1) Screen ......................... 16
Figure 14.
AIS to DSX (FLOS) Screen ................................. 16
Figure 15.
Restore Factory Defaults Screen .......................... 17
Figure 16.
Status Screen ......................................................... 17
Figure 17.
Port Status Screen ................................................. 18
Figure 18.
Status of All Ports Screen ..................................... 18
Figure 19.
Alarms Screen ....................................................... 19
Figure 20.
Alarm Reporting Screen ....................................... 19
Figure 21.
Alarm Provisioning Screen .................................. 20
Figure 22.
ES Threshold (15-Minutes) Screen ...................... 20
Figure 23.
SES Threshold (15-Minutes) Screen .................... 21
Figure 24.
UAS Threshold (15-Minutes) Screen .................. 21
Figure 25.
ES Threshold (24-Hours) Screen ......................... 22
Figure 26.
SES Threshold (24-Hours) Screen ....................... 22
Figure 27.
UAS Threshold (24-Hours) Screen ...................... 23
Figure 28.
Test Screen ............................................................ 23
Figure 29.
Port Test Screen .................................................... 24
Figure 30.
Loopback RT Screen ............................................ 24
Figure 31.
Loopback DSX Screen ......................................... 25
Figure 32.
Performance Monitoring Screen .......................... 25
Figure 33.
Port Performance Monitoring Screen .................. 26
Figure 34.
Protection Switch Screen ..................................... 26
Figure 35.
Protection Switch Activate Screen ....................... 27
Figure 36.
Circuit ID Screen .................................................. 27
Figure 37.
Port Current Circuit ID Screen ............................. 28
TABLES
Table 1.
Compliance Codes .................................................. 2
Table 2.
QFO-only Populated Total Access Chassis ........... 2
Table 3.
Pin-out for Pair 5 and 7 on TA 3000 ...................... 3
Table 4.
Pin-out for Pair 6 and 8 on TA 3000 ...................... 3
Table 5.
Pin-out for Pair 5 and 7 on TA 3010 ...................... 4
Table 6.
Pin-out for Pair 6 and 8 on TA 3010 ...................... 4
Table 7.
QFO-C Front Panel Indicators ............................... 7
61181300L1-5C
Total Access
Installation and Maintenance
Section 61181300L1-5C, Issue 3
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
TM
QFO-C
Table 8.
QFO-C Provisioning Options ................................. 8
Table 9.
QFO-C Menu Hierarchy ....................................... 11
Table 10.
QFO-C Specifications .......................................... 29
QF0-C
PWR
DSX
DSX
DSX
DSX
TST
ALM
Figure 1. Total Access QFO-C
1. GENERAL
This practice is an installation and maintenance guide
for the ADTRAN Total Access QFO-C, P/N
1181300L1, illustrated in Figure 1. See Table 5 for a
description of QFO-C front panel indicators.
Revision History
This is the third issue of this practice. This issue includes
the removal of the four-character display (FCD)
five-minute time out feature.
Features
The Total Access QFO-C carries up to four
asynchronous DS1 circuits over a single-mode fiber
pair with an optical budget of 22 dB (minimum). The
Total Access QFO-C has the following features:
Section 61181300L1-5C
Issue 3, October 2000
CLEI Code # M3O1CD0C_ _
1181300L1
#1
#2
#3
#4
ACT
A
P
S
GRN = NORM
YEL = MAN
1

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN QFO-C

  • Page 1 (FCD) five-minute time out feature. Features The Total Access QFO-C carries up to four asynchronous DS1 circuits over a single-mode fiber pair with an optical budget of 22 dB (minimum). The Total Access QFO-C has the following features:...
  • Page 2: Installation

    Wiring The QFO-C can only be used in a DSX-1 fed system. If the QFO-C module is to be mixed in the same shelf with other line technologies such as T1 or HDSL, refer to the wiring for that specific card type (See Section 3, Application Guide, in the Total Access 3000 System Manual).
  • Page 3: Table 3. Pin-Out For Pair 5 And 7 On Ta 3000

    Table 3. Pin-out For Pair 5 and 7 on TA 3000 61181300L1-5C Table 4. Pin-out For Pair 6 and 8 on TA 3000 Section 61181300L1-5C, Issue 3...
  • Page 4: Table 5. Pin-Out For Pair 5 And 7 On Ta 3010

    If the system is configured with only QFO-Cs, all four DSX-1 connections are made. The connections are made via four Amphenol connectors to Pair 5 through Pair 8 on the backplane. Table 5. Pin-out For Pair 5 and 7 on TA 3010 : e t s r i Total Access 3000 uses 64-pin Amphenol...
  • Page 5: Operation

    3. Position the QFO-C into the selected shelf slot. While holding the fiber cables between the two cable guides on the top of the QFO-C front panel, lower the card retention lever and slide the unit into the shelf assembly.
  • Page 6: Figure 3. Fiber Optic Receiver Cabling

    3. OPERATION The QFO-C transports up to four T1 signals from the near (CO/CEV) end to the far Remote Terminal (RT) end via a single mode fiber pair (transmit/receive) that has an optical budget up to 22 dB.
  • Page 7: Table 7. Qfo-C Front Panel Indicators

    The card is provisioned through the craft port on the SCU or by the FCD. Detailed procedures for provisioning the QFO-C start on page 11 with the section labeled Fiber (QFO-C) Main Menu. The screenshots are accompanied by steps to assist in provisioning the unit.
  • Page 8: Table 8. Qfo-C Provisioning Options

    UAS Threshold (24-Hour) Enters a specific UAS daily threshold that, when exceeded, will generate an alarm Circuit ID (one for each port) 32-character alphanumeric character field Table 8. QFO-C Provisioning Options Section 61181300L1-5C, Issue 3 Values Default In Service Out of Service-...
  • Page 9 For example, if the FCD is displaying QFO-C “20 MIN” on level 3 of Figure 4 and the ESCAPE command is issued, the “LB TOUT” menu displays. If the element is a read/write value, it maintains its original value.
  • Page 10 SELECT (<1.5 sec.) ESCAPE (1.5-3 sec.) Section 61181300L1-5C, Issue 3 61181300L1-5C...
  • Page 11: Table 9. Qfo-C Menu Hierarchy

    Fiber (QFO-C) Menu Screen This subsection provides procedures for entering the fiber menu screens to provision and maintain the QFO-C and the QFO-R. The Fiber menu hierarchy (QFO-C Main Menu screen and its eight submenu screens) is shown in Table 9.
  • Page 12: Figure 5. Fiber Main Menu Screen

    From the Total Access Main Screen Menu, type 4 and press Enter to select Access Modules. Type “1” and press Enter to select the Module Menus Screen. Choose the desired QFO-C slot number. The Fiber Main Menu Screen (Figure 5) will appear. Shelf:...
  • Page 13: Figure 7. Provisioning Screen

    Accessing the QFO-C Provisioning Screen 1. From the Fiber Main Menu Screen, type “2” and press Enter to select Provisioning. The Provisioning Screen (Figure 7) will appear. Shelf: Slot: Unacknowledged Alarms: Shelf: Slot: Unacknowledged Alarms: Service State 1. Port 0 2.
  • Page 14: Figure 9. Port Service Status Screen

    NOTE Port 0 is the QFO-C access module itself. Changing the Port Service State From the Service State Screen, type the desired port number and press Enter. The Port Service Status Screen (Figure 9) will appear. Shelf: Slot: Unacknowledged Alarms:...
  • Page 15: Figure 11. Dsx Equalization Screen

    NOTE Port 0 (all ports) “Out of Service” disables the entire module. Port 0 must be “In Service” for any Port 1 to 4 to be active. Changing the DSX Equalization 1. From the Provisioning of All Ports screen, type “1” and press Enter to select DSX Equalization.
  • Page 16: Figure 14. Ais To Dsx (Flos) Screen

    Enabling/Disabling AIS to DSX (Loss of T1) 1. From the Provisioning of All Ports Screen, type “3” and press Enter to select AIS to DSX (Loss of T1). The AIS to DSX (Loss of T1) Screen (Figure 13) will appear. 2.
  • Page 17: Figure 15. Restore Factory Defaults Screen

    Figure 15. Restore Factory Defaults Screen Shelf: Slot: Unacknowledged Alarms: 61181300L1-5C Accessing the Status Screen 1. From the QFO-C Main Menu Screen, type “3” and press Enter to select Status. The Status screen (Figure 16) will appear. Total Access System Restore Factory Defaults? Selection: ‘?’...
  • Page 18: Figure 17. Port Status Screen

    Viewing the Status of a Single Port From the Status Screen, type the number of the desired single port and press Enter. The Port Status Screen (Figure 17) will appear. Shelf: Slot: Unacknowledged Alarms: None Port 1 Status Port Loss of Signal Loop Back DSX Loop Back RT (Network) Loop Back RT (Customer)
  • Page 19: Figure 19. Alarms Screen

    Accessing the Alarms Screen From the QFO-C Main Menu Screen, type “4“ and press Enter to select Alarms. The Alarms Screen (Figure 19) displays. Shelf: Slot: Unacknowledged Alarms: None Shelf: Slot: Unacknowledged Alarm: None Alarms ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– QFO-C Fiber LOS from Facility...
  • Page 20: Figure 21. Alarm Provisioning Screen

    Changing Alarm Settings and Thresholds 1. From the QFO-C Main Menu screen, type “4” and press Enter to select Alarms. The Alarms Screen (Figure 19) will appear. 2. Type “2” and press Enter to select Alarm Provisioning. The Alarm Provisioning Screen (Figure 21) will appear.
  • Page 21: Figure 23. Ses Threshold (15-Minutes) Screen

    Setting the SES Threshold (15-Min.) 1. From the Alarm Provisioning Screen, type “2” and press Enter to select SES Threshold (15-Minute). The SES Threshold Screen (Figure 23) will appear. 2. Type “1” and press Enter to select 15 or type “2” and press Enter to select 75.
  • Page 22 Setting the ES Threshold (24-Hour) From the Alarm Provisioning Screen, type “4” and press Enter to select ES Threshold (24-Hour). The ES Threshold Screen (Figure 25) will appear. Type the number of the desired setting and press Enter. Shelf: Slot: Unacknowledged Alarm: None Shelf: Slot:...
  • Page 23: Figure 28. Test Screen

    Unacknowledged Alarms: Shelf: Slot: Unacknowledged Alarms: None 61181300L1-5C Setting Up Loopbacks for a Test From the QFO-C Main Menu Screen, type “5” and press Enter to select Test. The Test Screen (Figure 28) will appear. Total Access System MAJOR ALERT UAS Threshold (24 Hours): 7200 1.
  • Page 24: Figure 29. Port Test Screen

    Performing Loopback Testing 1. From the Test Screen, type the number that corresponds to the desired port and press Enter. The Port Test Screen (Figure 29) displays. Shelf: Slot: Unacknowledged Alarms: None Shelf: Slot: Unacknowledged Alarms: None 2. Type “1” and press Enter for remote loopback testing.
  • Page 25: Figure 31. Loopback Dsx Screen

    Shelf: Slot: Unacknowledged Alarms: None 61181300L1-5C Accessing the Performance Monitoring Screen 1. From the QFO-C Main Menu screen, type 6 and press Enter to select Performance Monitoring. The Performance Monitoring Screen (Figure 32) will appear. TOTAL ACCESS SYSTEM Loopback DSX: Disabled 1.
  • Page 26: Figure 33. Port Performance Monitoring Screen

    Shelf: Slot: Unacknowledged Alarms: None Switching the QFO-C from On Line to Protect From the QFO-C Main Menu Screen, type “7” and press Enter to select Protection Switching. The Protection Switching Screen for the Working card (Figure 34) will appear.
  • Page 27: Figure 35. Protection Switch Activate Screen

    Shelf: Slot: Unacknowledged Alarms: None 61181300L1-5C Setting the Port Circuit ID 1. From the QFO-C Main Menu Screen, type “8” and press Enter to select Circuit ID. The Circuit ID S creen (Figure 36) will appear. Total Access System ACT Activate 1.
  • Page 28: Maintenance

    Repair services are available if you return damaged units to ADTRAN. (Refer to the “Warranty and Customer Service” subsection of this Practice.) Refer to Table 10 for the QFO-C Multiplexer Module Specifications. 5. WARRANTY AND CUSTOMER SERVICE...
  • Page 29: Table 10. Qfo-C Specifications

    Supply Voltage ...-42 to -56 Vdc Maximum Power ... 8 Watts @ -48 Vdc Supply Current ...150mA at -48 Vdc, typical Dimensions ...5.5” Height; .75” Width; 10” Depth Weight ... 10.6 oz. in an anti-static bag 61181300L1-5C Table 10. QFO-C Specifications Section 61181300L1-5C, Issue 3...