Specifications; Standard Features; Optional Features - Detecto MedVue MV2 Owner's Manual

Medical weight analyzer
Table of Contents

Advertisement

Power Requirements . . . . . . . . 6 "C" cell Ni-Cad or NiMH batteries (not included) OR an
Operating Temperature . . . . . . +5 to +40 ºC
Display . . . . . . . . . . . . . . . . . . . Weight: 5-digit, seven segment, 22.23 mm (7/8") high LCD
Sensitivity . . . . . . . . . . . . . . . . . 0.83 uV/division (0 to 3.0 mV/V), Class III
Signal Input Range . . . . . . . . . 0 to 15mV max.4`
Transducer Excitation . . . . . . . 5.0 VDC
Number of Load Cells . . . . . . . up to 4 each 350
Load Cell Cable Length . . . . . . 30 feet (9 meters) max.
Resolution . . . . . . . . . . . . . . . . 6,000 divisions
Capacities . . . . . . . . . . . . . . . . 6,000 divisions commercial
Division Value . . . . . . . . . . . . . 1, 2, 5 or 10 x 1, 0.1, 0.01, 0.001
Sample Rate . . . . . . . . . . . . . . 1 to 100 samples per second selectable
Auto Zero Range . . . . . . . . . . . 0.5 or 1 through 9 divisions
Weighing Units . . . . . . . . . . . . . Kilograms (kg)
Keyboard . . . . . . . . . . . . . . . . . Membrane type with 19 keys
Enclosure Size . . . . . . . . . . . . . 248.9 mm W x 172.7 mm H x 45.7 mm D
Construction . . . . . . . . . . . . . . . Painted Steel

Standard Features:

Auto Shut-Off Feature
Selectable Sleep-Mode
StableSENSE
99 Tare Storage
Talley Roll
Transaction Storage

Optional Features:

Wi-Fi and Bluetooth, available in
Model MV2C
MVIP, Wired Ethernet Interface
Detecto DHR (Digital Height Rod)
1
®
StableSENSE
is a digital filter utilizing proprietary software algorithms to remove or greatly
reduce changes in the weight display resulting from movement on the scale platform.
®
StableSENSE
can be used with clinical scales to lessen the effects of the patient's
movement or vibration on the scale. Any application affected by vibration or movement on
the scale platform can benefit using StableSENSE

SPECIFICATIONS

optional 110-240 VAC 50/60 Hz 12 VDC 1.25A wall plug-in
AC power adapter (Cardinal part number MV2PWR).
Height: 4-digit, seven segment, 12.7 mm (1/2") high LCD
BMI: 3-digit, seven segment, 12.7 mm (1/2") high LCD
ID: 14-digit, 14 segment, 8.89 mm (.35") high LCD
(9.8 in W x 6.8 in H x 1.8 in D)
® 1
Adjustable Filtering
8555-0530-0M Rev E MedVue MV2 Owner's
Battery Charging
Serial I/O (Input/Output)
USB Device Port
Height Rod Port (for Optional Detecto
Digital Height Rod)
MV2PWR, 12VDC AC Power Adapter
®
Welch Allyn
WAConnect
®
.
1