Standard Function Keys
The 0 through 9 keys are used to enter alphanumeric data
during the setup and calibration as well as during normal
operation of the MV2.
To enter letters, you must press the key in succession until the
desired letter is displayed. This is similar to the way early cell
phone keypads operates. (Ex: If you want to enter the letter C,
you would need to press the 2 key four times).
NOTE: The 0, 1, and 7 keys have dual functions. They are used to enter numeric data during
setup and calibration as well as during normal operations. In addition, the 0 and 1 keys are
used to select no (0 = NO) or yes (1 = YES) to various prompts.
The 7 key is used to activate the Sleep mode feature. Pressing and holding the 7 key for
approximately 3 seconds will initiate the sleep mode to conserve power while the MV2 remains
unused. Sleep Mode requires the MV2 to remain at a stable zero weight. When enabled, the
display will show the date and time and the backlight will be turned off. Weight placed on the
scale or pressing any key will activate the MV2 and return it to weight mode.
This is the CLEAR (BACKSPACE) key. It is used to clear an incorrect entry
from the display without processing the data. If an incorrect entry is made,
press this key and re-enter the correct data. When entering the ID, pressing
this key will act as a "backspace" key (it will back up one space and delete the
character in that space). NOTE: The CLEAR key must be pressed before the
ENTER key to ensure the data is not processed.
This is the ENTER key. It serves two purposes. First, during setup, pressing
the ENTER key will accept the current displayed setting of the parameter.
Second, the ENTER key is used to signal completion of the entry of data (in
both setup and operation) and causes the scale to process the data entered.

nControl Feature

The MV2 includes support for nControl. nControl is
a PC based program that can design a ticket then
download the ticket information to the MV2. The
MV2 allows 1 programmable format (up to 512
characters in size) instead of the ASCII format
default ticket.
For more information on nControl, refer to the
nControl Fast Start Guide.
NOTE: If the ID/HEIGHT key is disabled, the
appropriate field will be left out when printing a
ticket.
10
KEYPAD FUNCTIONS, CONT.
8555-0530-0M Rev E MedVue MV2 Owner's
Time, mm/dd/yy
ID:
xxxxxxxxxxx
BMI:
xx.x
Height:
xx.x cm
Weight:
xxx.xuu G
xxx.xuu T
xxx.xuu N
SAMPLE TICKET