13 Inspection and maintenance
13.2 Removing the tube
CAUTION
Risk of crushing!
▶ While the tube holder is open, the ac-
tuator can move. Severe injury due to
crushing or shearing of the fingers.
Ensure that the actuator remains in
●
the open position during tube replace-
ment.
Do not reach into the tube crushing
●
area.
1. Move the actuator A to the open position.
b
2. Turn the locking ring b by 90° in the direction of the arrow.
ð The word "unlocked" can be read on the tube holder.
3. Open the tube holder 1.
4. Remove the tube.
GEMÜ Q50 eSyStep
Positioner (Code S0, S5, S6)
1
13.3 Disassembling the tube holder
1. Remove the tube (see "Removing the tube", page 46).
2. Loosen the fixing screw c using a hex driver.
3. Remove the tube holder 1.
13.4 Disassembling the compressor
Risk of crushing due to the compressor
shutting down!
▶ Severe injury due to crushing or
●
●
1. Remove the tube (see "Removing the tube", page 46).
2. Disassemble the tube holder (see "Disassembling the
tube holder", page 46).
3. Move the actuator A to the closed position.
4. Pull the compressor 2 out downwards.
46 / 53
1
c
CAUTION
shearing of the fingers.
Ensure that the actuator remains in
the open position while replacing the
compressor.
Do not reach into the tube crushing
area.
2
www.gemu-group.com