Events - GEM eSyStep Q50 Operating Instructions Manual

Motorized pinch valve positioner
Hide thumbs Also See for eSyStep Q50:
Table of Contents

Advertisement

11 Specific data IO-Link (pin 6)
11.4.36 Analog output
The analog output function can be set with the Analog Output parameter.
Index Sub-
Off-
Access
In-
set
Rights
dex
0xBA
1
0
R/W
2
8
R/W
3
16
R/W
4
32
R/W
Description of parameter values
Index name
Analog output

11.5 Events

The following IO-Link events can be transmitted.
Event
Device Hardware Fault
Motor Unable To Move
Device Temperature Over-Run
Emergency Power
Primary Supply Voltage Under-Run
Potifail Close
Potifail Open
Description – Events
Event
Device Hardware Fault
0x5000
Motor Unable To Move
0x8CE0
GEMÜ Q50 eSyStep
Positioner (Code S0, S5, S6)
Length
Index name
1 bit
Analog output
2 bits
16 bits
16 bits
Parameter
Values
Direction
0
1
Type
0
1
2
Min.
0 to Max
(0.0% to Max)
Max.
Min to 1000
(Min to 100%)
Description
The event occurs when a
hardware fault is detected.
The event occurs when the
motor is blocked.
Parameter
Type
Direction
Boolean
Type
uint:8
Min.
uint:16
Max.
uint:16
Specify direction of the set value output.
0 = Rise (rising)
1 = Fall (falling)
Determine signal output.
0 = 0 to 20 mA
1 = 4 to 20 mA
2 = 0 to 10 V
Determine minimum value of the output.
Determine maximum value of the output.
Mode
App/Disapp
Error
App/Disapp
Error
App/Disapp
Warning/Error
App/Disapp
Warning
App/Disapp
Error
App/Disapp
Warning
App/Disapp
Warning
Possible cause
Fault in valve position detec-
tion.
Parameter can no longer be
read when switching the
device on.
Valve is blocked (for example,
solid stuck in valve).
Valve corroded (rusted in
place).
End position can no longer be
reached (after replacing the
diaphragm).
42 / 53
Default
Values
0
0
1
1
0
1
2
0
0 to Max
(0.0% to Max)
1000
Min to 1000
(Min to 100%)
Description
Type
Code
0x5000
0x8CE0
0x4210
0x5100
0x5111
0x8CA5
0x8CA4
Troubleshooting
Contact GEMÜ Support
Check valve
Carry out initialization if valve
is OK
www.gemu-group.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q50 esystepS0S5S6

Table of Contents