GEM eSyStep Q50 Operating Instructions Manual page 37

Motorized pinch valve positioner
Hide thumbs Also See for eSyStep Q50:
Table of Contents

Advertisement

11.4.27 Calibration positions
The values of the factory calibration can be read out with the Calibration positions parameter.
The values are analog values of the potentiometer in the mechanical end positions of the actuator.
Index Sub-
Off-
Access
In-
set
Rights
dex
0x55
1
0
RO
2
16
RO
Description of parameter values
Index name
Calibration positions
11.4.28 Analog values
Different analog values can be read out with the Analog values parameter.
Index Sub-
Off-
Access
Index
set
Rights
0x60
1
0
RO
2
16
RO
3
32
RO
4
48
RO
Description of parameter values
Index name
Analog values
www.gemu-group.com
Length
Index name
12 bits
Calibration
positions
12 bits
Parameter
Values
Max.
0 ... 4092
Min.
0 ... 4092
Length
Index name
12 bits
Analog values
12 bits
12 bits
12 bits
Parameter
Values
Potentiometer
0 ... 4095
Supply voltage
0 ... 4095
Temperature
0 ... 4095
Set value (W)
0 ... 4095
Parameter
Type
Max.
uint:16
Min.
uint:16
Read out analog value of the potentiometer for the mechan-
ical end position OPEN.
Read out analog value of the potentiometer for the mechan-
ical end position CLOSED.
Parameter
Potentiometer
Supply voltage
Temperature
Set value (W)
Read out current analog value of the potentiometer.
Read out current analog value of the supply voltage.
Read out current analog value of the temperature sensor.
Read out current analog value of the set value.
37 / 53
11 Specific data IO-Link (pin 6)
Default
Values
0
0 ... 4092
4092
0 ... 4092
Description
Type
Values
uint:16
0 ... 4095
uint:16
0 ... 4095
uint:16
0 ... 4095
uint:16
0 ... 4095
Description
GEMÜ Q50 eSyStep
Positioner (Code S0, S5, S6)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q50 esystepS0S5S6

Table of Contents