GEM eSyStep Q50 Operating Instructions Manual page 10

Motorized pinch valve positioner
Hide thumbs Also See for eSyStep Q50:
Table of Contents

Advertisement

6 Technical data
6.6 Actuator's duty cycle and service life
Service life:
Duty cycle:
▶ The specified characteristics and values apply to the factory setting.
▶ With reduced forces, higher duty cycles and/or higher ambient temperatures are possible. At higher force settings the duty
cycle and/or ambient temperature is reduced.
▶ IO-Link: Index 0x90 - Subindex 2 - Force
6.7 Electrical data
Supply voltage Uv:
Rating:
Operation:
Reverse battery protec-
tion:
6.7.1 Analogue input signals – Control module Positioner (code S0, S5, S6)
6.7.1.1 Set value
Input signal:
Input type:
Input resistance:
Accuracy/linearity:
Temperature drift:
Resolution:
Reverse battery protec-
tion:
6.7.2 Digital input signals
Inputs:
Input voltage:
GEMÜ Q50 eSyStep
Positioner (Code S0, S5, S6)
Control operation - Class C according to EN 15714-2 (1,800,000 starts and 1200 starts per hour).
Open/Close duty - At least 500,000 switching cycles at room temperature and permissible duty
cycle.
Control module Positioner (code S0, S5, S6), Open/Close duty
100
90
80
70
60
50
40
30
Pinch valve
20
10
0
0
10
20
Ambient temperature [°C]
24 V DC ± 10%
Actuator size 0 (code 0A)
Stepper motor, self-locking
Yes
0/4 - 20 mA; 0 - 10 V (function selectable via IO-Link)
passive
250 Ω
≤ ±0.3% of full flow
≤ ±0.1% / 10°K
12 bit
Yes (up to ± 24 V DC)
Function selectable via IO-Link (see table Overview of available functions – Input and output sig-
nals)
24 V DC
30
40
50
60
NOTICE
20 W
10 / 53
70
www.gemu-group.com