Chapter 9 Pds Control Objects; Error Code (Obj. 603Fh)]; [Error Code (Obj. 603Fh: 00H)]; Controlword (Obj. 6040H)] - Mitsubishi Electric MELSERVO-JET Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-JET Series:
Table of Contents

Advertisement

9
PDS Control Objects
9.1

[Error code (Obj. 603Fh)]

[Error code (Obj. 603Fh: 00h)]

Data Type
Access
U16
RO
Description
The No. of the latest error which occurred after power-on is returned.
For example, when [AL. 118.1 Encoder communication circuit diagnosis in progress] occurs, this object returns "0118h".
9.2

[Controlword (Obj. 6040h)]

[Controlword (Obj. 6040h: 00h)]

Data Type
Access
U16
RW
Description
PDS status switching command is given, or control commands are returned and set.
Use bit 0 to bit 3 and bit 7 in the PDS status transition.
Bit
Name
0
SO
1
EV
2
QS
3
EO
4
OMS
5
OMS
6
OMS
7
FR
8
HALT
9
OMS
10
11
CPTL
12
CNTL
13
14
15
Mapping
Default
TxPDO
0000h
Mapping
Default
RxPDO
0000h
Description
Switch-on
Enable voltage
Quick stop
Enable operation
Differs depending on the value of [Modes of operation (Obj. 6060h)]. Refer to the following for details.
Page 76 [Bit 4: OMS]
Differs depending on the value of [Modes of operation]. Refer to the following for details.
Page 76 [Bit 5: OMS]
Differs depending on the value of [Modes of operation]. Refer to the following for details.
Page 76 [Bit 6: OMS]
Fault reset
0: Operation ready
1: Pauses the operation according to [Halt option code (Obj. 6050h)].
Refer to the following for details.
Page 76 [Bit 8: OMS]
Differs depending on the value of [Modes of operation]. Refer to the following for details.
Page 77 [Bit 9: OMS]
Positive Torque Limit switching
Negative Torque Limit switching
Range
Units
0000h to FFFFh
Range
Units
0000h to FFFFh
Save
Parameter
Impossible
Save
Parameter
Impossible
9 PDS Control Objects
9.1 [Error code (Obj. 603Fh)]
9
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-jet-g-n1 seriesMelservo mr-jet-10g-n1

Table of Contents