Error codes

Error code
Description
C1E0H
• Effective range error (Connection No./User name/Password)
i_uConnectionNo is not set within 1 to 16, i_sUserName not set within 4
to 14 characters, and i_sPassWord not set within 4 to 64 characters.
C1E1H
• Effective range error (Virtual input port number)
The set data is out of effective range: i_uVirtualInputPortNo is not set
within 1 to 32.
C1E2H
• Timeout error
No response is returned from the network camera after the command is
sent.
C1E3H
• User name/password setting error
Unregistered i_sUserName or i_sPassWord is set.
Other than the
Errors that occur in each processing for data communication between
above
the Ethernet-equipped module and external device, and errors that
occur in processing requests from the CPU module in the own station
8 FB LIBRARY DETAILS (FOR MELSEC iQ-R SERIES CPU MODULES (BUILT-IN ETHERNET PORT PART))
Action
Review and correct the input label, and execute the FB again.
Review and correct the input label, and execute the FB again.
Review and correct the following, and execute the FB again.
• When the constant scan time exceeding 500ms is set, set it
to 500ms or less, or leave it blank.
• Check that recording events are not overlapped due to
consecutive recording triggers that occur in a brief period of
time.
After performing the following, execute the FB again.
• Review and correct the input label.
• There may be no response from the network camera.
Restart the programmable controller and the network
camera.
 MELSEC iQ-R Ethernet User's Manual (Application)