Input label
Setting details
FB_EN
Connects with a device used as a recording trigger.
On: The FB is activated (a recording event is executed).
Off: The FB is stopped.
iw_ConnectionNo
Sets the connection number.
is_UserName
Sets the user name registered in the network camera.
is_PassWord
Sets the password registered in the network camera.
iw_VIPortNo
Specifies the port number of the virtual input for the recording event registered in the network
camera.
ib_VIPortState
Sets the virtual input port status.
On: The virtual input port status is enabled.
Off: The virtual input port status is disabled.
To activate the trigger, enable the virtual input port status. The virtual input port status cannot
be automatically disabled once it has been enabled. Therefore, disable the virtual input port
status after the event is started.
Output label
Setting details
FB_ENO
On: The execution command is on.
Off: The execution command is off.
FB_OK
The on state indicates that the virtual input port status on the network camera side has been switched.
FB_ERROR
The on state indicates that an error has occurred in the FB.
ERROR_ID
Returns the error code of an error occurred in the FB.
If recording events occur consecutively in a brief period of time and the recording duration of one event
overlaps the recording duration of the subsequent event, this FB may not be completed successfully and a
timeout error (C1E2H) may occur. Ensure that recording events do not overlap when this FB is executed.
When the virtual input port status of the network camera is turned on in this FB, it cannot be automatically
turned off. Therefore, the processing to turn off the virtual input port status of the network camera is required.
Therefore, when o_bOK (FB completed successfully) has been turned on, turn off i_bVirtualInputState to
execute this FB again.
FB_EN
ib_VIPortState
FB_OK
Virtual input port status of
the camera
Recording duration
(1) Video recording duration
(2) Pre-trigger recording time (Prebuffer)
(3) Post-trigger recording time (Postbuffer)
When recording video before and after turning on the recording trigger, the second recording cannot be
executed in the network camera without the above processing.
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
(2)
(3)
(1)
OFF
OFF
OFF
OFF
OFF
5 PROGRAMMABLE CONTROLLER SETTINGS
5.3 MELSEC-Q Series CPU Module
Setting example
1
"root"
"Pass1234"
9
1
59
5