Connection Of Devices - Mitsubishi Electric MELSEC iQ-R Series User Manual

Camera recording package
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Connection of devices

Connect the devices shown in the system configuration. ( Page 12 SYSTEM CONFIGURATION)
Ex.
(4)
(5)
(2)
(3)
No.
Device name
(1)
Q06UDVCPU
(2)
Network camera manufactured by
Axis Communications
(3)
MELIPC MI1000 (Network
storage)
(4)
Personal computer (Windows
(5)
PoE switching hub
(6)
Ethernet (twisted pair) cable
Precautions
Do not connect an Ethernet port of the MELSEC-Q series CPU module and a PoE port of a PoE switching hub. Doing so may
cause a failure.
(1)
Setting details
• IP address: 192.168.3.39 (Default)
• Subnet mask pattern: 255.255.255.0
• Default router IP address: 192.168.3.254
• IP address: 192.168.3.90
• Subnet mask: 255.255.255.0
• Default router: 192.168.3.254
• User ID: root
• Password: Pass1234
• Virtual input port: 9
• IP address: 192.168.3.30
• User ID: admin
• Password: PW1234
10)
IP address: 192.168.3.100
(6)
5 PROGRAMMABLE CONTROLLER SETTINGS
5.3 MELSEC-Q Series CPU Module
5
51

Advertisement