Connecting Inputs - Assa Abloy Norton 6300 Pull Side Series Installation And Instruction Manual

Full feature low energy operator
Table of Contents

Advertisement

13
Setting Accessory Dip Switches
A. For the following features, if dip switch is toward the text the feature is
turned on.
Latch Boost: Operator motor adds additional closing force in the latch
region to help overcome weatherstripping, stack pressure, etc.
Push and Go: Operator automatically opens after the door has been
manually pushed out of latch.
Power Assist: Operator motor assists the user while opening the door
manually by reducing the opening force the user feels.
Obstruction Detection Close: If the door hits an obstruction while
closing, the operator will reverse and reopen.
Lock Release: If door is in the closed position, the door is pulled in
slightly before an activation and after the door has closed to assist
with latch release / engagement.
Spare 1: Available Dip Switch for Special Application Requests.
Spare 2: Available Dip Switch for Special Application Requests.
14

Connecting Inputs

A. Use green 2-position connectors attached to board
to add any necessary inputs to the locations shown
at right. Definitions of inputs are below:
Input 1: Activation 1
Momentary contact closure of this input cycles the
door through a normally open / close cycle. Tied to
Open Delay 1.
Input 2: Activation 2
Momentary contact closure of this input cycles the door through a normal open / close cycle. Tied to
Open Delay 2.
Input 3: Toggle / Executive Mode
Momentary contact closure of this input sends a closed door to the open position or an open door to
the closed position.
Input 4: Blow Closed
Continuous contact closure of this input puts the operator in a passive closer mode where the door
functions as a typical door closer and accepts no activations. Once contact is removed, the unit goes
back to operator mode.
input 5: Blow Open
Continuous contact closure of this input triggers the operator to go to the open position and stay there
until the contact is removed. If the door is pulled away from the open position, the operator will go back
to open from any point.
(continue to next page)
Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
OFF
Page 12
ON
80-9363-0001-020 Rev 8 11/17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton 6310 pull sideNorton 6350 pull side

Table of Contents