Growatt MAX 80-150KTL3-X LV Series Installation & Operation Manual page 52

Table of Contents

Advertisement

AC overvoltage category
efficiency
Max. efficiency
Euro-eta
Protection devices
DC reverse-polarity
protection
DC switch
DC Surge protection
Insulation resistance
monitoring
AC surge protection
AC short-circuit protection
Grid monitoring
Anti-islanding protection
Residual-current monitoring
unit
String monitoring
Anti-PID function
AFCI protection
General data
Dimensions (W /H / D) in
mm
Weight
Operating
temperature
range
Altitude
Internal consumption at
Topology
Cooling
Protection degree
Relative humidity
DC connection
AC connection
Interfaces
Display
RS485/USB
PLC/GPRS/4G
Warranty: 5 /10 years
Certificates and approvals
98.80%
99.00%
Cable gland +OT terminal
52 / 56
编号:GR-UM-C -00
Category III
99.00%
98.50%
Yes
Yes
Type II
Yes
Type II
Yes
Yes
Yes
Yes
Yes
Optional
Optional
970*640*345mm
84kg
-30℃- +60℃
4000m
<1W(Note1)
Transformerless
Fan cool
IP66
0~100%
CN4U
LED/WIFI+APP
Yes
Optional
Optional
99.00%

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max 80-150ktl3-x mv series

Table of Contents