Page 1
MIN 7000TL-X2 MIN 8000TL-X2 MIN 9000TL-X2 MIN 10000TL-X2 Installation & Growatt New Energy Download Operation Manual Manual Shenzhen Growatt New Energy Co., Ltd 4-13/F, Building A,Sino-German (Europe) Industrial Park, Hangcheng Ave,Bao’an District, Shenzhen, China +86 0755 2747 1942 service@ginverter.com www.ginverter.com GR-UM-292-A-00...
Page 2
Index 1 Notes on this manual 1.1 Validity 1.2 Target Group 1.3 Additional information 1.4 Symbols in this document 1.5 Glossary 2 Safety 2.1 Intended Use 2.2 Qualification of skilled person 2.3 Safety instruction 2.4 Assembly Warnings 2.5 Electrical Connection Warnings 2.6 Operation Warnings 3 Product description 3.1 TL-X2 Overview...
Page 3
6 Electrical connection 11 Trouble shooting 11 1 Error Messages displayed on 6.1 Safety OLED 6.2 Wiring AC Output 11 2 System fault 6.3 Connecting the second protective 11 3 Inverter warning conductor 11 4 Inverter fault 6.4 Connecting the PV Array(DC input) 6.5 Connecting signal cable 6.6 Grounding the inverter 6.7 Active power control with smart...
Isolation Switch or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the Growatt equipment and/or other equipment connected to the Growatt equipment or personal injury. Alternating Current (AC)
AS4777,etc); however, certain safety precautions must be observed when installing and operating this inverter. Read and follow all instructions, cautions and warnings in this installation manual. If questions arise, please contact Growatt's technical services at +86 (0)755 2747 1942.
DANGER Persons with limited physical or mental abilities may only work Ø with the Growatt inverter following proper instruction and under constant supervision. Children are forbidden to play with the Growatt inverter. Must keep the Growatt inverter away from children.
3 Product description Symbol on the inverter 3.1 TL-X2 Overview Symbol Description Explanation Touch button.We can switch the Touch symbol OLEDdisplay and set parameter by touching. Inverter status LED color LED status Standby Green 0.5s on and 2s off Normal Green Solid Inverter...
If there are a batch of inverters need to be stored, the maximum layers for original MPP voltage range 60V~550V carton is four. Ø After long term storage, local installer or service department of GROWATT should AC nominal voltage 220V/230V/240V perform a comprehensive test before installation. AC grid frequency 50/60 Hz 3.5 The advantage of the unit...
Radios, telephone, television, etc) Ø Do not stay closer than 20 cm to the inverter for any length of time unless it is absolutely necessary. Growatt assumes no responsibility for compliance to EMC Ø regulations for the complete system Ø...
5.2 Selecting the installation location ≥300mm Ø This is guidance for installer to choose a suitable installation location, to avoid potential damages to device and operators. Ø The installation location must be suitable for the inverter's weight and dimensions Min.30cm Min.30cm Min.30cm Min.30cm...
5.3.2 Fixed the inverter on the wall Ø Please make sure the inverter is installed at the right place.The inverter can't install close to trunk. Falling equipment can cause serious or even fatal injury, never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wall after carefully checking.
6 Electrical connection The AC wiring step: Decisive Voltage Class (DVC) indicated for ports 1.Uninstall the parts of the AC connection plug from the accessory bag. Port Name Class 2.Pass the 3 wires (L or L1,N or L2 and PE wires) through the AC shield,connect them to the power grid, and then crimp the OT terminal.
Make sure the cable polarity is correct and voltage is less than 550V. If the inverter is not equipped with a DC switch but this is mandatory in the country of installation, install an external DC switch. The following limit values at the DC input of the inverter must not be exceeded: Max current Max current...
Page 15
Definition Definition Power +12V DRM 5 supply for external DRM 6 relay(≤2W) RS 485A1 DRM 7 Fig 6.11 Click! Signal for communication RS 485B1 DRM 8 Fig 6.15 DRMS RefGen Step 3 Push the threaded sleeve to connection terminal until both are locked tightly on the inverter.
6.6 Grounding the inverter Manufacturer Eastron The inverter must be connected to the AC grounding conductor of the power distribution Type SDM120CT-M(40mA) grid via the ground terminal (PE) . General Specifications Because of the transformerless design, the DC positive pole and DC Voltage AC (Un) 230V negative pole of PV arrays are not permitted to be grounded.
The following table describes how we can connect Eastron SDM 120CT-M(40mA): 6.8.1 16Pin socket pin assignment Assignment for inverters capable of both charging and COM Socket Pin No. Meter Pin NO. Description Meter Connection discharging CT-P(White) DRM 5 CT-input CT-N(Black or Blue) DRM 6 DRM 7 N-in...
6.9.2 Danger information Danger of fire from electric arc Only test the AFCI for false tripping in the order described below. Do not deactivate the AFCI permanently. If an "Error 200" message is displayed, the buzzer alarms, an electric arc occurred in the PV system.
The AC cable is correctly connected. ü Region” as below: ü The DC cable is correctly connected. ü The communication cable is correctly connected. Growatt The country is set correctly. ü PV inverter 7.1 Start the inverter 7.1.1 Touch control Country/Aera...
7.2.2 Set inverter COM address MIN TL-X2 contains five types Power Quality Response Modes: Volt-Var, Volt-watt, Fixed PF, Reactive power, Power limit.If you want to change the The default COM address is 1.We can change COM address as described below: Power Quality Response Modes please refer to chapter 7.3.1.
7.3 Advanced setting 7.3.2 Generation & Export limitation control and Power Sensor setting Single touch to switch display or make the number +1. 7.3.1 Reset Country,Region and Power Quality Response Modes(PQRM) Double touch to confirm you setting. Single touch to switch display or make the number +1. Control type: Double touch to confirm you setting.
Page 22
7.4 Communications Under the permission given by your energy provider, the ratio of your system output power divided by the rated power of the inverter is called Limit Rate.For instance,if the 7.4.1 RS485 energy provider only accepts 8kVA/kW from your 10kW system, then the Limit Rate of 10kW inverter is 80.0%.
Maintenance,Repair and Cleaning 9 Prior to removal of any cover for maintenance or repair, turn off the switch on the AC and DC sides WARNING 9.1 Checking Heat Dissipation If the inverter regularly reduces its output power due to high temperature, please improve the heat dissipation condition.
An error message will be displayed on the OLED screen when a fault occurs. The faults EU directives. The entire EU Declaration of Conformity can be found at www.ginverter.com. consist of system fault and inverter fault. You may be advised to contact Growatt in some situation, please provide the following information. Information concerning the inverter: Serial number Ÿ...
1.Restart the invert. Warning 203 still exist, please contact Growatt short Error: 201 high 2.If error message still exists,contact Growatt. customer service to replace the POWER board. 1.Disconnect the DC switch immediately. The DC input voltage 1.After shutdown,Check the dry 2.Check the voltage of each PV string with...
Restart inverter, if problem still exist, change 13.3 Storing the Inverter Error: 420 GFCI fault power board, or contact Growatt. Store the inverter in a dry place where ambient temperatures are always between -30°C and +60°C. The data sampled by the...
14 Technical Data Model 14.1 Specification 7000TL-X2 8000TL-X2 9000TL-X2 10000TL-X2 Specifications Model Adjustable power factor 0.8leading…0.8lagging 7000TL-X2 8000TL-X2 9000TL-X2 10000TL-X2 Specifications THDi <3% Input data(DC) AC grid connection type Single phase Max. recommended PV 13.5k power(for module STC) Overvoltage category PV:II AC:III Others:I Max.
Page 28
LAN monitor with USB interface All specifications are subject to change without notice. Shipped to a Growatt service centre for repair, or repaired on-site, or exchanged for a 14.2 DC connector and Isolator info replacement device of equivalent value according to model and age.
Certificates 7000-10000TL-X2 CE , IEC 62109, AS4777,UL1741,ABNT NBR 16149 16 Contact If you have technical problems about our products, contact the GROWATT Serviceline. We need the following information in order to provide you with the necessary assistance: Ø Inverter type Ø...
Need help?
Do you have a question about the MIN 7000TL-X2 and is the answer not in the manual?
Questions and answers