1>Please ensure that the DC side and AC side of the inverter have been disconnected
before cleaning or replacement of the fan.
1) Turn off DC switch.
2) Disconnect DC terminals from inverter (Users need tools to disconnect the DC
connection terminals).
3) Turn off AC switch.
2>Remove the screws on the fan guards with a cross screwdriver. it is shown as below.
Fig 9.1 External fan view
Fig 9.2 Internal fan view
3>Disconnect the wire connector of the fans with a flat head screw driver and remove
the fans from the fan guards, it is shown as below.