Growatt TL3-X Series Installation & Operation Manual

Growatt TL3-X Series Installation & Operation Manual

Hide thumbs Also See for TL3-X Series:

Advertisement

Growatt New Energy
Download
Manual
Shenzhen Growatt New Energy CO.,LTD
No.28 Guangming Road, Shiyan Street, Bao'an District,
No.28 Guangming Road, Shiyan Street, Bao'an District,
Shenzhen, P.R.China
Shenzhen, P.R.China
T
+86 755 2747 1942
+86 755 2747 1942
E
service@ginverter.com
service@ginverter.com
www.ginverter.com
www.ginverter.com
W
GR-UM-212-A-00
Installation
&
Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TL3-X Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Growatt TL3-X Series

  • Page 1 Installation & Operation Manual Growatt New Energy Download Manual Shenzhen Growatt New Energy CO.,LTD No.28 Guangming Road, Shiyan Street, Bao’an District, No.28 Guangming Road, Shiyan Street, Bao’an District, Shenzhen, P.R.China Shenzhen, P.R.China +86 755 2747 1942 +86 755 2747 1942 service@ginverter.com...
  • Page 2 Index 1 Notes on this manual 1.1 Validity Applicable personnel Symbols in this document 2 Safety 2.1 Product description and features 2.2 Qualification of skilled person 2.3 Safety instruction 3 Product overview Appearance overview Dimensions Storage environment 4 Unpacking inspection 5 Installation 5 1 Basic installation requirements 5.2 Mounting wall mount...
  • Page 3 13 Troubleshooting 7 Debugging 13 1 Error message 13 2 Syetem error 14 Manufacturer warranty 8 Working mode Normal mode Failure mode Shutdown mode 15 Decommissioning 9 OLED display and touch 15.1 Dismantling the inverter 9.1 Boot display buttons 15.2 Packing the inverter 9.2 OLED display wake up 15.3 Storing the inverter 9.3 Function setting...
  • Page 4: Notes On This Manual

    If the procedure or practice is not properly implemented or followed, it may cause damage or destruction of part or all of the Growatt device and/or other equipment connected to the Growatt device, or cause personal injury.
  • Page 5: Product Description And Features

    Abbreviation for "Alternating Current” photovoltaic panels into alternating current, and send it to the grid in a three-phase manner. Growatt MOD 3-15K TL3-X series inverter can be connected to 2 strings (12-15K Abbreviation for "Direct Current” TL3-X and 7-11K TL3-X-AU can be connected to three strings), has 2 maximum power Energy tracking point trackers, so suitable for connection 2 Set of arrays of different panels.
  • Page 6: Qualification Of Skilled Person

    Persons with limited physical or mental abilities may only work 3.During installation,except for the wiring terminals,please do not move other parts with the Growatt inverter following proper instruction and under inside the chassis; constant supervision. Must keep the Growatt inverter away from 4.All electrical installations must comply with local electrical safety standards;...
  • Page 7: Appearance Overview

    Product overview 2.3.3 Operation Warnings 3.1 Appearance overview Ensure all connectors are sealed and secure during operation. Ø Although designed to meet all safety requirements, some parts Ø and surfaces of inverter are still hot during operation. To reduce the risk of injury, do not touch the heat sink at the back of the PV- inverter or nearby surfaces while inverter is operating.
  • Page 8: Unpacking Inspection

    Unpacking inspection 3.2 Dimensions Before opening the inverter package,please check whether the outer package is damaged.After unpacking,please check whether the appearance of the inverter is damaged or lack of accessories.If there is damage or missing parts,please contact the dealer. Fig 3.2 Size and weight: Fig 4.1 Model...
  • Page 9: Installation

    Installation 5.1 Basic installation requirements The wall on which the inverter is mounted must be sturdy and can withstand the Ø weight of the inverter for a long time (refer to the specifications in Chapter 12 for the weight of the inverter); The installation location must match the size of the inverter;...
  • Page 10: Install The Wall Mount

    5.2 Install the wall mount 5.2.1 Install the wall mount To prevent electric shock or other damage, be sure to check the wall for power or other piping before opening the hole in the wall. Danger Fig 5.7 Specifications of wall mount Secure the wall mount as shown, do not let the screws flush with the wall, instead expose Fig 5.4 Installation Environment 2 to 4 mm.
  • Page 11: Inverter Wiring

    Inverter wiring 6.1 Security There may be a high voltage in the conductive part of the inverter, which may cause electric shock.Therefore, when installing the inverter,make sure that the AC and DC sides of the inverter are Danger powered off. Static electricity may damage the electronic components of the inverter.Anti-static measures should be taken during the replacement or installation of the inverter.
  • Page 12 AC connection steps: Preparation before wiring: 1.Pass the 5 wires (A,B,C,N and PE wires) through the AC shield,connect them to the Connect the protective ground wire (PE) power grid,and then crimp the O/U terminal. Connect the inverter to the grounding bar through the protective earth (PE) to achieve grounding protection.
  • Page 13: Dc Side Wiring

    1.Pass the 5 wires (A,B,C,N and PE wires) through the AC shield,connect them to the power grid, and then crimp the O/U terminal. Maximum wire length 10-12mm Wire ross-sectional area MOD TL3-X series and MOD TL3-X-AU series 6mm² 8 mm² 6.3 DC side wiring Fig 6.5 Sunlight will generate voltage on the battery panel.The high voltage...
  • Page 14: Connect The Signal Cable

    Connect DC terminal Moisture and dust penetration can damage the inverter Make sure that the waterproof cable gland is firmly tightened. Ø If the cable connector is not installed correctly,the inverter may be Positive connector Ø Positive metal terminal Cables damaged due to the penetration of moisture and dust.All warranty claims Note 4~6mm²...
  • Page 15: Grounding The Inverter

    6.5 Grounding the inverter 2. Push the threaded sleeve into the socket and tighten the waterproof gland. Inverter side The inverter must be connected to the AC grounding conductor of the power distribution grid via the ground terminal (PE) . Because of the transformerless design, the DC positive pole and DC negative pole of PV arrays are not permitted to be grounded.
  • Page 16: Inverter Demand Response Modes (Drms)

    6.7 Inverter demand response modes (DRMS) 6.7.3 Using the Power Control Interface for EU This series inverter has the function of demand response modes, We use 16-Pin socket as RRCR inverter DRMS connection. DRMS application description Ø Applicable to AS/NZS4777.2:2015 or Commission Regulation (EU) 2016/631.
  • Page 17 Debugging 6.8 AFCI(Optional) 1.Close the DC switch on the inverter.As long as the input DC voltage is greater 6.8.1 Arc-Fault Circuit Interrupter (AFCI) than 140V,the inverter display will show the following information:No mains connection error,the inverter LED will turn red. In accordance with the National Electrical Code R, Article 690.11, the inverter has a If other information is displayed,please refer to Chapter 8.If you encounter any system for the recognition of electric arc detection and interruption.
  • Page 18: Working Mode

    When the sunlight is weak or there is no sunlight,the inverter will automatically stop Model:S03B00D running.When in shutdown mode,the inverter basically does not consume energy from Growatt 00T00P00U00M0 the grid or solar panels,and at the same time,the inverter's display screen and LED lights PV inverter will be turned off.
  • Page 19: Function Setting

    9.3 Function setting Tips and disclaimers When the inverter leaves the factory, the grid-connected voltage and frequency are set in The inverter can support multiple touch modes: single touch, two accordance with NB/T 32004-2013 or the latest domestic standard; consecutive touches, three consecutive touches, long press for 5S. If the grid voltage is close to or higher than the domestic legal requirements, the inverter Different types of taps have different functions.
  • Page 20: Communication And Monitoring

    Communication and Monitoring 10.1 RS485 Set Language Set paramerter This series of inverters provide two RS485 ports. You can monitor one or more inverters English via RS485. The other RS485 port is used to connect a smart meter (stand-alone anti- Double touch backflow function).
  • Page 21: Maintenance And Cleaning

    If the inverter regularly reduces its output power due to high temperature, please Faults include system faults and inverter faults. improve the heat dissipation condition. Maybe you need to clean the heat sink. In some cases, you may be advised to contact Growatt, please provide the following information. 11.2 Cleaning the Inverter Information about the inverter::...
  • Page 22 Warning Warning Description Suggest Description Suggest message message 1Unplug the U disk; 1.Check whether the meter is turned on; U S B o v e r c u r r e n t 2.Reconnect the U disk after shutdown; Warning 207 Warning 401 The meter is abnormal 2.Check whether the connection between the protection...
  • Page 23 13.3 System error Error code Description Suggest Error code Description Suggest 1.Restart the machine; A b n o r m a l D C Error 400 2.If the fault information still exists,contact the 1.Check the panel terminal wiring after shutdown; component offset manufacturer.
  • Page 24: Manufacturer Warranty

    Manufacturer warranty Error code Description Suggest Please refer to the warranty card. 1.Restart the machine; Error 413 Drive exception 2.If the fault information still exists,contact the manufacturer. 1.Restart the machine; Decommissioning Error 414 Memory exception 2.If the fault information still exists,contact the manufacturer.
  • Page 25: Eu Declaration Of Conformity

    8000TL3- Specifications •2011/65/EU RoHS Directive and its amendment (EU)2015/863 Shenzhen Growatt New Energy Technology Co. Ltd confirms that the Growatt inverters Input data(DC) and accessories described in this document are in compliance with the above mentioned EU directives. The entire EU Declaration of Conformity can be found at www.ginverter.com.
  • Page 26 Model Model 3000TL3- 4000TL3- 5000TL3- 6000TL3- 7000TL3- 8000TL3- Specifications Specifications 9000TL3-X 10TL3-X 11TL3-X 12TL3-X 13TL3-X 15TL3-X Protection devices Input data(DC) DC reverse-polarity Max. recommended PV protection 13500W 15000W 15000W 18000W 19500W 22500W power(for module STC) DC switch Max. DC voltage 1100V DC Surge protection typeII OPT...
  • Page 27 Australian models Model Specifications 9000TL3-X 10KTL3-X 11KTL3-X 12KTL3-X 13KTL3-X 15KTL3-X Model 3000TL3- 4000TL3- 5000TL3- 6000TL3- 7000TL3- 8000TL3- Specifications X-AU X-AU Protection devices DC reverse-polarity Input data(DC) protection Max. recommended PV 4500W 6000W 7500W 9000W 10500W 12000W DC switch power(for module STC) DC Surge protection typeII OPT Max.
  • Page 28 Model Model 3000TL3- 4000TL3- 5000TL3- 6000TL3- 7000TL3- 8000TL3- 9000TL3- 10TL3-X- 11TL3-X- Specifications Specifications 12TL3-X 13TL3-X 15TL3-X X-AU X-AU X-AU Protection devices Input data(DC) DC reverse-polarity Max. recommended PV protection 13500W 15000W 15000W 18000W 19500W 22500W power(for module STC) DC switch Max.
  • Page 29 USB interface LAN monitoring module Weight 16.5kg The inverter can be repaired on site or transported to the Growatt service center for Operating temperature -25°C ... +60°C repair, or it can be replaced with a new one based on the model and service life of the range (>45°CDerating)
  • Page 30: Compliance Certificates

    Compliance certificates Contect us If you have technical questions about our products, please contact the Growatt New With the appropriate settings, the unit will comply with the requirements specified in Energy Service Hotline. We need the following information to provide you with the the following standards and directives (dated: Dec./2018):...