5.3
MIG/MAG welding
5.3.1
Connecting the intermediate hose package to the power source
With this machine series, the earth cable on the intermediate hose package must not be connec-
ted to the welding machine or wire feeder! Remove the earth cable or push back into the hose
package!
Item Symbol
1
2
3
4
5
6
•
Insert cable plug on the workpiece lead into the welding current socket "
the right.
•
Insert cable plug on the control lead into the 19-pole connection socket and secure with crown nut (the
plug can only be inserted into the connection socket in one position).
•
Plug the welding current lead plug (wire feeder) into the
the right.
Some wire electrodes (e.g. self-shielded flux cored wire) must be welded using negative polarity.
Use the push-button for welding current polarity (pole reversal) to reverse the welding current
polarity (+/-) without having to swap the welding current leads. Signal lamps located above the
welding current sockets indicate the selected welding current polarity (+/-).
099-002061-EW501
05.05.2020
Description
0
Workpiece
Connection socket, welding current (workpiece)
Wire feed unit
Intermediate hose package
19-pole connection socket
Control cable for remote control and/or wire feeder
Connection socket, welding current (electrode holder)
Welding current connection for wire feeder
Design and function
Figure 5-22
connection socket and lock by turning to
MIG/MAG welding
" and lock by turning to
31