Open system functionality

Virtual network interface

10.5
Virtual network interface
For the data exchange between the control and Windows 10 IoT, the internal virtual network
interface is available.
The functional range corresponds to a standardized Gigabit Ethernet interface.
The interface is preconfigured by default and can be directly used.
SFTP ("SSH File Transfer Protocol") serves to directly access the directory structure of the
SD card.
All TCP/IP-based network protocols and services available in the control as library function
can be used.
Connect the »PLC Designer« to the controller via the virtual interface
The »PLC Designer« engineering tool can be directly installed in the open system (Windows 10
IoT) of the controller.
The 'localhost' gateway address must be entered in the connection settings for the device.
After "Search network", the c750 controller responds with device identification, IP and
MAC address.
See also:
4Establish connection between controller and »PLC Designer«
Parameter
Address
Name / setting range / [default setting]
0x2462:001
Active virtual port settings: IP address
• Read only
0x2462:002
Active virtual port settings: Subnet
• Read only
0x2462:003
Active virtual port settings: Active gateway
• Read only
0x2462:005
Active virtual port settings: MAC address
• Read only
90
^ 21
Information
Display of the active IP address.
Display of the active subnet mask.
Display of the active gateway address.
Display of the MAC-ID.