IMPORTANT
Le remplacement de composants pourrait compromettre l'admissibilité à la Classe I,
Division 2.
Sample Hazardous Location Label
The following is an example of the RUGGEDCOM RSG909R hazardous location label:
Figure 2.1
2.3

Mounting the Device

The RUGGEDCOM RSG909R is designed for maximum mounting and display flexibili-
ty. It can be equipped with adapters that allow it to be attached to a DIN rail or panel.
IMPORTANT
Heat generated by the device is channeled outwards from the enclosure. As such, it
is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the
device to allow for some convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduc-
tion of ambient temperature and improve the long-term reliability of all equipment
mounted in the rack space.
Note
For detailed dimensions of the device with either DIN rail or panel hardware installed,
refer to
RUGGEDCOM RSG909R
Installation Manual, 02/2020, C79000-G8976-1388-09
Compliance Label (Example)
"Dimension Drawings (Page
32)".